B&B Electronics EIR505-xx User Manual

B&B Electronics EIR505-xx User Manual

Five port managed industrial ethernet switches

Advertisement

Quick Links

Product Description

Model EIR505-xx
Documentation Number: EIR505-xx_5107m
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA
Phone (815) 433-5100 -- General Fax (815) 433-5105
Phone (815) 433-5100 -- General Fax (815) 433-5105
Website:
www.bb-elec.com
Sales e-mail:
orders@bb-elec.com
-- Fax (815) 433-5109
Technical Support e-mail:
support@bb.elec.com
-- Fax (815) 433-5104
European Headquarters
B&B Electronics
Westlink Commercial Park -- Oranmore, Co. Galway, Ireland
Phone +353 91-792444 -- Fax +353 91-792445
Website:
www.bb-europe.com
Sales e-mail:
sales@bb-europe.com
Technical Support e-mail:
support@bb-europe.com
B&B Electronics Mfg. Co. Inc. -- December 2007
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Advertisement

Table of Contents
loading

Summary of Contents for B&B Electronics EIR505-xx

  • Page 1: Product Description

    Product Description Model EIR505-xx Documentation Number: EIR505-xx_5107m 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109 Technical Support e-mail: support@bb.elec.com...
  • Page 3: User Manual

    Five Port Managed Industrial Ethernet Switches User Manual Manual Documentation Number: EIR505-xx_5107m Table of Contents B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 4 Notice The contents of this manual are based on the firmware, kernel, and hardware versions listed below. Firmware Version V1.29 Kernel Version V2.05 Hardware Version A5.00 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 5: Fcc Warning

    FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 6: Table Of Contents

    Content FCC Warning............v CE Mark Warning ............. v Introduction ..............1 Features ..............1 Package Contents ............ 2 Hardware Description..........3 Physical Dimension ..........3 Front Panel............... 3 Reset Button...............3 Bottom View ............. 4 DIP-switch ..............4 LED Indicators............5 Ports .................
  • Page 7 DIN-Rail Mounting ..........11 Wall Mount Plate Mounting ........13 Hardware Installation..........14 Network Application ..........15 X-Ring Application..........15 Coupling Ring Application ........16 Dual Homing Application ........17 Web-Based Management ........18 About Web-based Management ......18 Preparing for Web Management ......18 System Login............
  • Page 8 Port-based VLAN .............25 802.1Q VLAN ..............27 IP Address.............. 31 SNTP Configuration ..........32 IP Security .............. 35 RSTP Configuration ..........36 System Configuration ............36 Per Port Configuration ............38 X-Ring ..............39 QoS Configuration..........41 IGMP ..............43 Security Manager ........... 45 Configuration Backup ..........
  • Page 9: Troubles Shooting

    Troubles shooting............ 50 Technical Specification ........... 51 Manual Documentation Number: EIR505-xx_5107M Table of Contents B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 11: Introduction

    Introduction The Elinx EIR505 series of Industrial Managed Ethernet Switches provide powerful functionality in a small package. Designed for industrial applications, these switches are highly reliable. Features Conforms to IEEE 802.3 10Base-T, 802.3u 100Base-TX/100Base-FX 5-port 10/100TX industrial switch (Fiber Optic models have 1 100FX port) RJ-45 ports support auto MDI/MDI-X Store-and-Forward switching architecture...
  • Page 12: Package Contents

    Package Contents 5 Port Managed Industrial Switch One DIN-Rail (attached to the switch) One Panel mount plate and six screws User manual 5 10/100TX with X-Ring Web Management User Manual Industrial switch Wall Mount Plate Screws DIN-Rail If any item is missing or damaged, contact B&B Electronics for a replacement.
  • Page 13: Hardware Description

    Hardware Description Physical Dimension (W x H x D) 2.13in x 5.31in x 4.13 in (54mm x 135mm x 105mm) Front Panel EIR505 Front Panel Reset Button The reset button is used to restart the reboot the switch or restore it to the factory default configuration.
  • Page 14: Bottom View

    Bottom View The bottom panel of the EIR-505-xx industrial switch consists of one terminal block connector with two DC power inputs and one DC IN power jack. Bottom Panel of the industrial switch DIP-switch The six position DIP-switch is used to configure the relay alarm operation mode and the master ring operation mode.
  • Page 15: Led Indicators

    Enable port Alarm. Disable port Alarm Enable port Alarm. Disable port Alarm Enable port Alarm. Disable port Alarm Enable port Alarm. Disable the master ring function. Enable the switch as the ring master in the X-Ring group. LED Indicators There are 7 diagnostic LEDs located on the front panel. They provide real-time status information.
  • Page 16: Ports

    The switch is off or no power input is available The switch is the master of X-Ring Green group R.M. (Ring Master) The industrial switch is not the master of an X-Ring group Green Power source 1 is available Power 1 Power source 1 is not available Green Power source 2 is available...
  • Page 17: Pin Outs

    RJ-45 Pin Assignments Pin Number Assignment All ports on this switch support automatic MDI/MDI-X operation. Straight-through cables can be used for all network connections. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable.
  • Page 18: Cabling

    Cross Over Cable Schematic Fiber Port There is one 100Base-FX port. The fiber port is SC type connector in multi mode (2Km) or single mode (30Km). Connect the fiber port as described below. ATTENTION This is a Class 1 Laser/LED product. Do not stare into the Laser/LED Beam.
  • Page 19: Wiring The Power Inputs

    Kilometers are supported. Fuse 50 or 62.5/125 um for multi-mode fiber cable. Distances up to 2Kmare supported. Wiring the Power Inputs V- V+ V- V+ 1. Insert the positive and negative wires into the V+ and V- connector on the terminal block connector 2.
  • Page 20: Wiring The Fault Alarm Contact

    Wiring the Fault Alarm Contact The fault alarm contact are located in the middle of terminal block connector as shown below. Insert the wires and set the Dipswitch to “ON”. When a power source fails or a link fault occurs, it will be detected and cause an open circuit.
  • Page 21: Mounting Installation

    Mounting Installation DIN-Rail Mounting Rear Panel of the switch DIN-Rail Use the screws to attach the DIN-Rail to the industrial switch To remove the DIN-Rail, reverse the step 1. Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 22 First, insert the top of DIN-Rail into the track. Then, lightly push the DIN-Rail into the track. Ensure the DIN-Rail is tightly secured to the track. To remove the industrial switch from the track, reverse steps above. Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc –...
  • Page 23: Wall Mount Plate Mounting

    Panel Mounting Follow the steps below to mount the industrial switch with the Panel mount plate. 1. Remove the DIN-Rail from the industrial switch. 2. Place the wall Panel plate on the rear of the industrial switch. 3. Use the screws to attach the Panel plate to the industrial switch 4.
  • Page 24: Hardware Installation

    Hardware Installation 1. Unpack the Industrial switch. 2. Ensure the DIN-Rail is tightly screwed to the Industrial switch. If not, refer to DIN-Rail Mounting section for DIN-Rail installation. To panel mount the Industrial switch, refer to Panel Mounting section. 3. Apply power to the switch (refer to the Wiring the Power Inputs section).
  • Page 25: Network Application

    Network Application X-Ring Application The EIR505 series of Industrial Switches incorporate the X-Ring Protocol to ensure network reliability and system restoration within 300 ms in the event of a connection failure. The X-Ring algorithm is similar to the spanning tree protocol (STP) algorithm but it has faster recovery time.
  • Page 26: Coupling Ring Application

    Coupling Ring Application If the network has more than one X-Ring group, the coupling ring function is used to connect them and add redundancy. This ensures that transmissions between the two ring groups will not fail. The figure below is an example of the coupling ring application.
  • Page 27: Dual Homing Application

    Dual Homing Application The Dual Homing function is used to prevent a connection loss between the X-Ring group and the upper level/core switch. Assign a port in each X-ring group to be the Dual Homing ports The Dual Homing function can only be used when the X-Ring function is active.
  • Page 28: Web-Based Management

    Web-Based Management About Web-based Management The switch has an embedded HTML web site residing in flash memory. This site offers advanced management features and allows the switch to be configured from anywhere on the network. The web site is designed for Internet Explorer 5.0 and uses Java Applets to reduce bandwidth consumption, enhance access speed, and present an intuitive user interface.
  • Page 29: System Login

    System Login Launch Internet Explorer on the PC. Enter “http:// “+” the IP address of the switch”, in the address window and then Press “Enter”. The login screen will appear. Enter the user name and password. Press “Enter” or “OK”, the home screen will appear. Function Menu Bar Home Interface Panel Figure Display...
  • Page 30: Port Status

    Port status Shows the status of each port Port: Displays the port number Type: Displays the speed and mode, ex: 100TX = 100Mbps Link: Displays the ports status (up or down) State: Displays the ports status (disabled or enabled). Unlinked is displayed as “off ”...
  • Page 31: Port Statistics

    Port information interface Port Statistics Displays port statistics. Click Clear button to reset. Port Statistics Interface Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 32: Port Control

    Port Control Used to set up the port. Select the port by scrolling down the Port column. The current port information will be displayed in the table below. State: Enables or disables the port. Negotiation: Sets the negotiation mode to Auto, Nway (specify the speed/duplex of the port and enable auto-negotiation), or Forced.
  • Page 33: Switch Settings

    Switch Settings Used to assign the system name, location and to view system information System Name: Assigns a name to the switch. The maximum length is 64 bytes System Location: Assigns a physical location for the switch. The maximum length is 64 bytes System Description: Displays the description of switch.
  • Page 34: Port Mirroring

    Port Mirroring Port mirroring is a method to monitor traffic in switched networks. This is accomplished by mirroring the traffic going in and out of the monitored ports to a specifically designated port (the mirror port). Port Mirroring Mode: Sets the mirror mode. Select disable to disable port mirroring.
  • Page 35: Vlan Configuration

    VLAN configuration A Virtual LAN (VLAN) can be thought of as a broadcast domain that exists within a switch or a defined set of switches. By grouping switch ports into VLANs, traffic flooding is limited since devices can only communicate directly with devices belonging to the VLAN.
  • Page 36 VLAN – Port Base interface Click to add a new VLAN group. The EIR505 series supports up to 64 VLAN groups Enter Group name, VLAN ID and select the members of VLAN group Click Apply Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 37: 802.1Q Vlan

    VLAN—Port Base Add interface The VLAN group will be displayed after apply is clicked Click Next Page to view the next VLAN group Delete button to delete unwanted VLANs Edit button to modify existing VLANs [NOTE] If the configuration is not saved, it will be lost when the switch is powered off 802.1Q VLAN Tagged-based VLAN is an IEEE 802.1Q specification which allows VLANs...
  • Page 38 uses a technique to insert a “tag” into the Ethernet frame. The tag contains a VLAN Identifier (VID). When the 802.1Q VLAN is enabled, all ports on the switch belong to a default VLAN (VID 1). The default VLAN can’t be deled. The EIR505 series will support up to 64 VLAN groups.
  • Page 39 Group Name: assign a name for the new VLAN VLAN ID: fill in a VLAN ID. The default is 1 From the Available ports box, select ports to add to the VLAN group and click button 802.1q VLAN –Add interface Click Next to bring up the configuration interface:...
  • Page 40 Select outgoing frames as VLAN-Tagged frames or untagged and then click Apply Port VID: Configure port VID settings Port VLAN ID: enter the port VLAN ID And then, click Apply To reset to the default values, click Default button Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc –...
  • Page 41: Ip Address

    802.1q VLAN – Port VLAN ID interface [NOTE] If the configuration is not saved, it will be lost if the switch is powered off. IP Address Configure the IP Settings and DHCP client function DHCP Client: Use to enable or disable the DHCP client function. When the DHCP client function is enabled, the industrial switch will be assigned an IP address from the network DHCP server.
  • Page 42: Sntp Configuration

    Client is enabled. The default IP is 192.168.10.1. Subnet Mask: Assign the subnet mask of the IP address. This is not required if the DHCP Client is enabled. Gateway: Assign the network gateway. The default gateway is 192.168.10.254. Click Apply IP configuration interface SNTP Configuration SNTP (Simple Network Time Protocol) allows the switch to synchronize its...
  • Page 43 ADT - Atlantic -3 hours 9 am Daylight AST - Atlantic Standard -4 hours 8 am EDT - Eastern Daylight EST - Eastern Standard -5 hours 7 am CDT - Central Daylight CST - Central Standard -6 hours 6 am MDT - Mountain Daylight MST - Mountain...
  • Page 44 European Winter SWT - Swedish Winter EET - Eastern European, Russia +2 hours 2 pm Zone 1 BT - Baghdad, +3 hours 3 pm USSR Zone 2 ZP4 - Russia Zone 3 +4 hours 4 pm ZP5 - Russia Zone 4 +5 hours 5 pm ZP6 - Russia Zone 5...
  • Page 45: Ip Security

    [NOTE] If the configuration is not saved, it will be lost when the switch is powered off. SNTP Configuration IP Security IP security function grants 10 specific IP addresses permission to access the switch through a web browser for the switch management. Enable the IP Security: Mark the check box to enable Security IP 1 ~ 10: Enter up to 10 specific IP address.
  • Page 46: Rstp Configuration

    IP Security Interface RSTP Configuration The Rapid Spanning Tree Protocol (RSTP) is an evolution of Spanning Tree Protocol (STP). It provides a faster spanning tree convergence after a topology change. The switch will auto detect a device that is running STP or RSTP protocol.
  • Page 47 Hello Time (1-10): The time that the control switch sends out a BPDU packet to check RSTP status. Enter a value between 1 and 10. Forward Delay Time (4-30): The number of seconds a port waits before changing from its Rapid Spanning-Tree Protocol learning and listening states to the forwarding state.
  • Page 48: Per Port Configuration

    Per Port Configuration Configure path cost and priority of every port 1. Select the port in Port column 2. Path Cost: The cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000 3.
  • Page 49: X-Ring

    RSTP – Per Port Configuration interface X-Ring X-Ring provides network redundancy similar to the Spanning Tree and Rapid Spanning Tree Protocols. However, recovery time is greatly reduced when the X-Ring protocol is used. The protocol identifies one switch as the Ring Master.
  • Page 50 ring master has the rights to negotiate and place a command to other switches in the X-Ring group. If more than one switch is in master mode, the software will select the switch with lowest MAC address number as the ring master.
  • Page 51: Qos Configuration

    X-Ring Interface [NOTE] 1. When the X-Ring function is enabled, the RSTP function must be disabled. 2. If the configuration is not saved, it will be lost when the switch is powered off. QoS Configuration Qos Policy: select the Qos policy rule Using the 8,4,2,1 weight fair queue scheme: The switch will follow 8:4:2:1 rate to process priority queue from Highest to lowest.
  • Page 52 COS only: The port will follow the COS priority assigned TOS only: The port will follow the TOS priority assigned COS first: The port will follow COS priority first, and then another priority rule TOS first: The port will follow TOS priority first, and then another priority rule COS priority: Set the COS priority level 0~7 TOS priority: The system provides 0 to 63 TOS priority levels.
  • Page 53: Igmp

    QoS configuration Interface IGMP The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffic by using switches, routers, and hosts that support IGMP. Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch.
  • Page 54 Message Description A message sent from an IGMP router or switch Query requesting a response from each host belonging to the multicast group. A message sent by a host indicating that the host Report wants to be or is a member of a given group. A message sent by a host indicating that the host has is no longer a member of a specific multicast Leave Group...
  • Page 55: Security Manager

    Security Manager Use to change the web management login user name and password. User name: enter the new user name(The default is “root”) Password: enter the new password(The default is “root”) Confirm password: reenter the new password Click Apply [NOTE] If the configuration is not saved, it will be lost when the switch is powered off.
  • Page 56: Tftp Backup Configuration

    TFTP Restore Configuration interface TFTP Backup Configuration Save current flash ROM value to the TFTP server TFTP Server IP Address: Enter the TFTP server IP Backup File Name: Enter the file name Click Apply TFTP Backup Configuration interface TFTP Update Firmware Use to update firmware.
  • Page 57: Factory Default

    TFTP Update Firmware interface Factory Default Reset the Switch to the default configuration. NOTE: The IP Address, subnet mask, default gateway, username, and password will remain as configured by the user. Click Default Factory Default interface System Reboot Reboot the switch in software reset Reboot Click System Reboot interface...
  • Page 58: Save Configuration

    Save Configuration Save the configuration to flash memory. If the switch is powered off without saving the configuration, all changed configuration will lost Click Save Flash Save Configuration Interface Rate Control Set up each port’s bandwidth rate and packet limitation type Limit Packet type: Select the packet type to filter.
  • Page 59 [NOTE] 1. If the configuration is not saved, it will be lost when the switch is powered off. 2. Qos and Rate control cannot exist at the same. Rate Control Interface Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 60: Troubles Shooting

    Trouble shooting Verify the power supply is correct (12-48V DC) Do not exceed 48V DC. Ensure the proper UTP cable is used for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps connections or 100Ω Category 5 cable for 100Mbps connections. Ensure that the length of any twisted-pair connection does not exceed 328 feet (100 meters).
  • Page 61: Technical Specification

    Technical Specification IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE802.3x Flow Control and Back-pressure Standards IEEE802.1d spanning tree / IEEE802.1w rapid spanning tree IEEE802.1p class of service IEEE802.1Q VLAN Tag Protocol CSMA/CD Provides Web interface management and one Management default button for system default setting Store and forward switching architecture...
  • Page 62 Per port: Link/Activity (Green), Full duplex/Collision (Yellow) Per unit: Power (Green), Power 1 (Green), Power 2 (Green), Fault (Yellow), Master (Green) 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable EIA/TIA-568 100-ohm (100m) Network Cable 100Base-TX: 2-pair UTP/STP Cat. 5 cable EIA/TIA-568 100-ohm (100m) SC (Multi-mode): 50/125um~62.5/125um SC (Single mode): 9/125um~10/125um...
  • Page 63: Rapid Spanning Tree

    port based Tag based Quality of service IPv4 Type of service X-Ring 300 ms Recovery Time Port based VLAN and IEEE802.1Q Tag VLAN. VLAN Both port based and Tag based VLAN groups (up to 64). IEEE802.1d spanning tree and IEEE802.1w Spanning tree rapid spanning tree.
  • Page 64 Install DIN rail and panel mount Alarm One 24VDC, 1A relay output. TFTP firmware update Firmware update TFTP configuration backup and restore. DHCP client function to obtain the IP address DHCP client from a DHCP server. Ingress packets filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 128kbps, 256Kbps, 512Kbps, 1MB, 2MB, 4MB, and...
  • Page 65 FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN-6100-4-4, CE EN6100-4-5, CE EN6100-4-6 EN60950 Safety IEC60068-2-32 (Free fall), IEC60068-2-27 Stability testing (Shock), IEC60068-2-6 (Vibration) Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...

This manual is also suitable for:

Elinx eir505 series

Table of Contents