Port Mirroring Commands Set; Commands Set - B&B Electronics e-Linx EIRP610-2SFP-T User Manual

Table of Contents

Advertisement

Port Mirroring Commands Set

Netstar Commands
monitor
[RX|TX|Both]
monitor rx
[Port ID]
monitor tx
[Port ID]
show monitor
show monitor
no monitor
802.1x Commands Set
Netstar Commands
8021x enable
8021x system radiusip
[IP address]
134
Level Description
Configure source port of
I
monitor function
Set RX destination port
G
of monitor function
G
Set TX destination port
of monitor function
P
Show port monitor
information
Show port monitor
I
information
Disable source port of
I
monitor function
Level Description
Use the 802.1x global
G
configuration command
to enable 802.1x
protocols.
G
Use the 802.1x system
radius IP global
configuration command
to change the radius
server IP.
Manual Documentation Number EIRP610-2SFP-T – 0912m
Command Sets
Example
switch(config)#interface
fastEthernet 2
switch(config-if)#monitor RX
switch(config)#monitor rx 2
switch(config)#monitor tx 3
switch#show monitor
switch(config)#interface
fastEthernet 2
switch(config-if)#show monitor
switch(config)#interface
fastEthernet 2
switch(config-if)#no monitor
Example
switch(config)# 8021x enable
switch(config)# 8021x system
radiusip 192.168.1.1
www.bb-elec.com