7 Installation

7.1.

Precautions During Set Up

Copy machine performance and the copy quality is subject to and dependant on environmental conditions.
To maintain good performance, quality, and safe operation, observe the following precautions:
1. For safe operation and to avoid trouble, do not install the system under the following conditions:
• High temperature, high humidity, low temperature or low humidity
• Sudden changes in temperature or humidity
• Exposed to direct sunlight
• Dusty environment
• Poorly ventilated location
• Exposed to chemical gases (such as ammonia gas)
• Exposed to strong vibration
• Exposed to direct air current (ex. Air conditioner vent)
2. The weight of machine is 91 lb (41 kg) or more with options. It must be installed on a firm and leveled
surface.
3. The maximum power consumption is 1.5 kW. Depending on the product destination, the wall outlet
must be rated for 120 VAC or 220-240 VAC accordingly. It must also be protected for at least 15 amps
for 120 VAC, or 10 amps for 220-240 VAC. If you are in doubt about a power source, ensure that a
qualified electrician checks the outlet. Do not connect any other devices to the wall outlet designated
for this machine. (Do not use an extension cord)
4. Make sure the outlet is properly grounded. (Do not ground to gas or water pipe)
5. Install in an area that meets or exceeds the minimum space requirement.
7.2.

Unpacking

Visually check the condition and contents of the box for completeness or any shipping damage before
installation.
Remove all filament tapes used to secure the Fuser and Process Units during shipment.
7.3.

Installation Procedure

Note:
1. Refer to each individual Installation Instructions when installing Stands or other Optional Kits.
2. The following machine illustrations, depicts a DP-1810P with a standard configuration of 1 Paper Tray.
3. The scanner is held in place by a Metal Shipping Bracket to prevent damage during transit.
Do not turn the Power Switch ON before unlocking the scanner.
4. The machine is shipped from the factory with the Pressure Roller locked in the opened position to
avoid the possibility of damaging the Pressure Rollers.
Do not turn the Power Switch ON before unlocking the Pressure Roller.
Edition 2.0