3
After the printer has completed startup, turn off the printer and replace the operator panel.
Note: If the operator panel display has failed, the printers' startup cycle is complete when the driver motor and
fans shut down, and the machine is quiet.
4
After installing the new operator panel, start the printer into diagnostics mode, and allow the printer to go through
a complete startup cycle and the display to go to Ready.
5
If the problems persist, leave the new operator panel in the machine, place the old controller board back in the
machine, and start it up. After the machine startup, shut down the machine, and install the new controller board.
After installing the new controller board, restart the machine, and let it go through the startup cycle.
After this procedure is completed successfully, there is no need to adjust any settings.
If the above procedure fails, you must contact the technical support center for further instructions.

eSF solutions backup

If a technician needs to replace the RIP board, the steps below should be taken to backup the eSF solutions and settings:
1
POR the printer into invalid engine code mode.
2
Open a Web browser, and navigate to the printer Web page.
3
Navigate to Settings, and click the link.
4
Navigate to Solutions, and click the link.
5
Navigate to Embedded Solutions, and click the link.
6
On the Embedded Solutions page, select the apps to be exported by clicking the selection box next to the app.
7
Choose Export.
If the Web page cannot be accessed, or an error persists despite trying to boot in Invalid Engine code mode, then there
is no way to back up the eSF apps. The technician needs to make the customer aware that the applications and their
settings could not be saved.
There is a size limit on the export file - 128kb. Because of this, it is recommended that you don't use the "global" backup
found in Settings > Import/Export > Export Shortcuts File, Export Settings File, Export Embedded Solutions Settings
File and Export Security Setups File. Customers with a large number of applications or settings may exceed the file size
limit and have information truncated in the exported file.