Regulations; Standards And Directives; Duty To Obtain A Permit And Provide Notification; Installation Location - Buderus Logano plus GB312 Installation And Maintenance Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

3

Regulations

In its design and operational characteristics, this boiler
complies with the following standards:
• EN 677
• EN 437, EN 483
• Gas Equipment Directive 2009/142/EC
• Efficiency Directive 92/42 EEC
• EMC Directive 2004/108/EC
• Low Voltage Directive 2006/95/EC
3.1

Standards and directives

For installation and operation observe the following
regulations and requirements in your country:
• local building regulations regarding the installation
conditions
• local building regulations regarding ventilation and
extract air systems and the chimney connection
• regulations regarding connection to the power supply
• the technical rules of the gas supply utility concerning
the connection of the gas burner to the public gas
mains
• the regulations and standards regarding safety
equipment of water heating systems
• the installation instructions for heating system installers
3.2
Duty to obtain a permit and provide
notification
B Ensure that the installation of a gas condensing boiler
is notified to and approved by the relevant gas supply
utility.
B Please note that regional approvals may be required for
the flue system and the connection of the condensate
outlet to the public sewerage system.
B Prior to commencing the installation, notify the
responsible flue gas inspector and the waste water
authority.
Logano plus GB312 - Subject to technical modifications.
3.3

Installation location

NOTICE: System damage due to frost!
B Site the heating system in a room safe
from the risk of frost.
DANGER: Risk of fire from flammable
materials or liquids!
B Never store flammable materials or liquids
in the immediate vicinity of the boiler.
NOTICE: Boiler damage through
contaminated combustion air or
contaminated air in the vicinity of the boiler!
B Never operate the boiler under dusty
conditions or where the atmosphere is
contaminated with corrosive substances.
These might be, for example, paint shops,
hairdressing salons and agricultural
operations (manure).
B Never operate boilers where
trichloroethene, halogenated
hydrocarbons or other corrosive chemical
substances are used or where such
material is stored. These substances are
contained, for example, in certain
adhesives, solvents, cleaning agents and
paints.
B In such cases, always select balanced flue
operation in a separate, hermetically
sealed installation room that has a fresh air
supply.
3
Regulations
13

Hide quick links:

Advertisement

Table of Contents
loading