Audio Alarm Verification Connections (AAV, "Listen-In")

Using the UVS System with UVCM Module
Refer to the connection diagrams below. One diagram shows connections when a 4286 Phone Module
is used, the other shows connections when the 4286 is not used.
Connections use one of the on-board triggers.
U L
UL installations using the AAV feature must use the ADEMCO UVCM module (part of the ADEMCO UVS
system).
Suggested AAV Module: ADEMCO UVS
Notes
• Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80 Menu mode:
select zone type "60" and output action 1 (close for 2 seconds).
• For voice session monitoring, connect a zone to module terminals 6 & 7, and program the zone as
zone type 81 (*56 Menu mode).
E.g., Using output 18 for the trigger, program an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
UVCM
MODULE
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = ON
2 = OFF
3 = OFF
3 = OFF
4 = OFF
4 = ON
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 15. Connection of AAV Unit When Not Using a 4286 Phone Module
CONTROL
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
FALLING VOICE TRIG
GND
+12VDC IN
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
4
5
Mounting and Wiring the Control
21
22
23
24 25
EOL
RING
TIP
RED (R)
GREEN (T)
GREY (R)
BROWN (T)
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
TO
PREMISES
HANDSET
EARTH
GROUND
RJ31X
INCOMING
PHONE LINE
2-19