Advertisement

DEVICE
6150ADT Touchpad
6160VADT Voice
Touchpad
6270ADT Touch Screen
8132ADT iCenter
5881/5882 RF Receiver
5883 Transceiver
4219 Zone Expander
4204 Relay Unit
4229 Zone Expander/Relay
Unit
4286 Phone Module
*
*
*
*
*
*
*
(Current available from Aux. terminals = 600 mA max.) †
AUXILIARY DEVICE CURRENT DRAW WORKSHEET
CURRENT
40mA
(70mA alarm)
60mA
(190mA alarm)
††
180mA/220mA
(280mA alarm)
††
150mA/350mA
††
(200mA/400mA
alarm)
60mA
80mA
30mA
15/180mA ‡
30/100mA ‡
300mA
# UNITS
TOTAL
CURRENT
TOTAL =
Mounting and Wiring the Control
*
If using hardwire devices such
as PIRs, refer to the
specifications for that particular
unit's current draw.
In UL installations, maximum
current draw from the Auxiliary
Output and the Alarm Output
combined must not exceed
600 mA (500 mA max from
Auxiliary Output).
Figures are for relays
OFF/relays ON.
††
backlighting off/backlighting on