Zone Lists; About Zone Lists; Zone List Programming - ADT Safewatch Pro 3000EN Installation And Setup Manual

Hide thumbs Also See for Safewatch Pro 3000EN:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

About Zone Lists

Zone lists let you group individual zones for use with certain system actions. The following table
shows the available zone lists and their purposes:
List No.
Used for...
1, 2
general purpose (GP)
3
chime-by-zone
4
cross zones (see note at right)
5
night stay zones
6
dial delay disable or GP
7
unlimited reports or GP
8
general purpose
9
zones that activate Pager 1
10
zones that activate Pager 2
11
zones that activate Pager 3
12
zones that activate Pager 4

Zone List Programming

Zone List programming involves:
1. Selecting an appropriate zone list number;
2. Adding the desired zone numbers to be included in that list.
Start Zone List Program Mode by pressing ✱ 81 while in Data Programming mode. The following
prompts are displayed :
*81 Menu Mode
PROMPT
Zone List No.
(00 = Quit)
01
01 Enter Zn Num.
(00 = Quit)
00
01 Del Zn List?
0 = No 1 = Yes
0
(see field *26 to enable option)
VALID ENTRIES
Zone List Number
01-12 = zone list number
[∗] to continue
Zone Number
01-64 = zone numbers
followed by [∗] to
accept each zone
00 to continue
Deleting Zone Lists
0 = don't delete list
1 = delete this zone list
[∗] to continue
Notes
• Any list may include any or all of the system's zone
numbers.
• A zone list can be assigned to more than one output relay.
• Zone List 4: When creating zone list 4 for cross zoning,
include only zones assigned to zone types 3, 4, or 5. Do not
include zones that have delays (entry/exit zones, interior
w/delay) or 24-hour zones, as these zone types may produce
unpredictable operation and may not function as intended.
See field *85 for Cross Zone Timer option.
• Zone List 6: See field *50 for Dial Delay Disable option.
• Zone List 7: See field *93 for Unlimited Reports option.
EXPLANATION
Enter the Zone List Number to program (or 00 to end these
entries). Press [ ✱ ] to advance.
In the following displays, zone list 01 has been selected for
programming.
Enter each zone number to add to the zone list, followed by
pressing [ ✱ ] (example, 01 ✱ , 02 ✱ , 03 ✱ ). After all zones are
entered, press 00 to continue.
IMPORTANT: Do not include fire zones in zone lists that are
used to STOP device actions.
To delete the zone list, enter 1. All zones in the zone list will
be deleted automatically and the system returns to the Zone
List No. prompt.
To save the zone list, enter 0.
S E C T I O N

Zone Lists

( ∗ ∗ ∗ ∗ 81 Menu Mode)
7
7-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterpreneur 3000enSecurity manager 3000en

Table of Contents