System Communication; Report Code Format (Ademco Contact Id) - ADT Safewatch Pro 3000EN Installation And Setup Manual

Hide thumbs Also See for Safewatch Pro 3000EN:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Report Code Format (Ademco Contact ID)

The Ademco Contact ID Reporting Format comprises the following:
4- or 10-digit subscriber number.
1-digit event qualifier ("new" or "restore").
3-digit event code.
2-digit Partition No.
3-digit zone number, user number, or system status number (see the following page).
Ademco Contact ID Reporting takes the following format:
where:
in the ZZZ location.
Format
Handshake
Contact ID
1400–2300Hz
CCCC(CCCCCC) Q EEE GG ZZZ
CCCC(CCCCCC) =
Q = Event qualifier, where:
E = new event , and R = restore
EEE = Event code (3 hexadecimal digits)
Note: For a complete list of event codes, refer to the central office receiver
manual.
GG = Partition Number (system messages show "00")
ZZZ = Zone/contact ID number reporting the alarm, or user number for open/close
reports. System status messages (AC Loss, Walk Test, etc.) contain zeroes

System Communication

Transmits Data
DTMF (10 cps)
Customer (subscriber) ID (4 or 10 digits depending on format
selected)
S E C T I O N
Kissoff
Transmit Time
1400Hz
Under 3 secs.
1 3