3000EN Series: Installation Instructions
No. of Reports In Armed Period
*93
per Zone (Swinger Suppression)
Entry 1: No. of Report Pairs
1 = 1 report pair per zone per armed
period
2 = 2 report pairs per zone per armed
period
Entry 2 (SIA Installations): Unlimited
0 = restrict reports to the setting in
entry 1
1 = unlimited reports for zones listed in
zone list 7
Download Phone Number
*94
Enter up to 20 digits as follows: 0–9, #
+11 for "∗", # + 12 for "#", # + 13 for a
pause.
Ring Count For Downloading
*95
0–15 = number of rings before control
picks up phone line .
† NOTE: If "15" is entered to bypass
an answering machine, and a 4286
Phone Module is included in the
system, you should note the
following:
When calling in from an off-
premises phone, the user should
make the initial call, allow 1 or 2
rings only, then hang up. The user
should then call again. The phone
module will now seize the line, and
2 long tones sound, followed by the
usual voice prompt for the access
code. If this procedure is not
followed, phone module operation
will not be possible.
Command to Initialize CSID and
*96
Subscriber Account Number
Command to Reset System to
*97
Factory Default Values
Command to Exit Program Mode
*98
(with installer code lockout)
Command to Exit Program Mode
*99
4-10
Reports Enable
This option can be used to limit the number of alarm/alarm
restore message pairs per zone sent to the central station in
an armed period. Swinger suppression applies to burglary
zones only.
Use entry 1 to limit reports to one or two report pairs as
desired, or use entry 2 for zones that require unlimited
reporting; these zones ignore the setting in entry 1. If
selected, enter appropriate zones in zone list 7.
SIA installations: Entry 1 must be set for option 1 or 2.
Enter the phone number of the downloading computer.
Do not fill unused spaces. End field by entering ∗. To clear
entries from field, press ∗94∗.
Field *
U L Downloading may be performed only if a technician is at the site.
Refer to the chart below and program this field accordingly.
phone
answer
down-
module machine loading Set field ∗ ∗ ∗ ∗ 95 to...
yes
no
no
yes
yes
no
yes
no
yes
yes
yes
yes
no
no
no
no
yes
no
no
no
yes
no
yes
yes
This is a command function, not a data field. Use this
command, if necessary, to reset all subscriber account
numbers and the internal CSID to the factory default values.
This is a command function, not a data field. Pressing ∗97
resets all data fields to the factory default values (shown on
the Program Form).
IMPORTANT: Do not press ∗97 to load defaults if any
programming has been done previously—data already
programmed into the system will be changed!
Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming
mode if ∗ 98 was used to exit, you must first power the system
down. Then power up again, and press [∗] and [#] at the same
time, within 50 seconds of powering up.
Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [∗] and [#] at
the same time, within 50 seconds of power-up.
1-14 (not 0)
greater than rings set on
answer machine (e.g., if ans.
machine is 4 rings, set this
field to 5). This allows access
to the phone module if the
answer machine is turned off.
1-14 (not 0)
15 (bypasses answer
machine)†
0
0
1-14
15