3000EN Series: Installation Instructions
01 Activated By:
Zone List
"A"
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
6-4
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[∗] to continue
Zone List
01-08 = zone list
[∗] to continue
Zone Type
see list at right
Select where the initiating event for this output definition is
to occur as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to "A" prompt)
2 = zone type (go to "B" prompt)
3 = zone number (go to "C" prompt)
If you enter "0," the following prompt appears:
Delete?
0 = NO, 1 = YES
If zone list was selected, this screen appears. Otherwise skip to
the next row.
Enter the desired zone list associated with this output number.
NOTE: Do not use pager zone lists 09-12 in output definitions.
Press [ ✱ ] to continue.
Enter the zone list event that will activate this output.
Enter Event
Alarm
1
NOTE: For alarm, fault, and trouble, an event on ANY zone in
the list activates the output, but ALL zones in the list must be
restored before the output is restored.
Press [ ✱ ] to continue and skip to the "Output Action" prompt.
If zone type was selected, this screen appears. Otherwise skip
to the next row.
Enter the desired zone type associated with this output
number. See below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Trouble Day/Alarm Night
01 = Ent/Exit #1
06 = 24 Hr Silent
02 = Ent/Exit #2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower 09 = Fire
10 = Interior w/Delay
12 = Monitor Zone
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
36 = **At Bell Timeout***
21 = Arming–Away
38 = Chime
22 = Disarming
39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time 41 = **AC Power Failure
33 = Any Burglary Alarm 42 = **System Battery Low 67 = Bell Fail
43 = Comm. Failure
52 = Kissoff
54 = Fire Zone Reset
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
†† when used with an output function, the carbon monoxide zone type
activates upon CO alarms only. Does not activate for trouble conditions
§ automatically set when appropriate AVS Quick Command performed.
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
Any partition
0
Press [ ✱ ] to continue and skip to the "Output Action" prompt.
Press 1 to delete this
output definition.
0 = restore; 1 = alarm;
2 = fault; 3= trouble
14 = Carbon Monoxide††
16 = Fire w/verification
23 = No Alarm Response
24 = Silent Burglary
25 = 24-Hr Non-Alarm
77 = Keyswitch Zone
81 = AAV Monitor Zone
90-93 = Configurable
58 = Duress
60 = AAV
61 = AVS/GSMV
62 = AVS/GSMV
66 = Function Key†
68 = Telco line cut
78 = Keyswitch Red LED
79 = Keyswitch Green LED
0 = any partition; 1 = partition 1;
2 = partition 2; 3 = common
§
session begin
§
session end