Various System Trouble Displays

Alpha Display
ALARM CANCELED
EXIT ALARM
CHECK
ALARM 1xx
FAULT 1xx
CHECK 1xx
SYSTEM LO BAT
LO BAT
TELCO FAULT
Busy-Standby
Modem Comm
no display
Comm. Failure
Open Circuit
Long Rng Trbl
Bell Failure
RCVR Jam
KEYPAD LOW BAT
Phone Okay
Dialer Off
Test in Progress
Upload Completed
Upload Failed
Fixed Disp.
Meaning
CA
Will appear if an exit or interior zone contained a fault during closing at
the time the Exit Delay ended (e.g., exit door left open), but the system
was disarmed during the Entry Delay time. The alarm sounder and
touchpad sound continuously, but stop when the system is disarmed. No
message will be transmitted to the central station.
EA
Will appear when the Exit Delay ends if an exit or interior zone contained
a fault during closing. Alarm sounder and touchpad sound continuously
until the system is disarmed (or timeout occurs). "Exit Alarm" message is
sent to the central station. Also results if an alarm from an exit or interior
zone occurs within 2 minutes after the end of an Exit Delay.
CHECK
Indicates that a problem exists with the displayed zone(s) and requires
attention.
1xx
Indicates that communication between control and a zone expander or
1xx
wireless receiver is interrupted, where "xx" is the device address. Check
1xx (91)
the wiring and DIP switch settings on the units.
If field *199 is set to "1," all ECP module problems are displayed as "91."
If there are wireless sensors in the system, the Check condition may also
be caused by some change in the environment that prevents the receiver
from receiving signals from a particular sensor
BAT
With no zone number indicates the system's main standby battery is weak.
BAT
With a zone number and a once-per-minute beeping at the touchpad
indicates that a low-battery condition exists in the wireless sensor
displayed (zone "00" indicates a wireless touchpad). If the battery is not
replaced within 30 days, a "CHECK" display may occur.
Some wireless sensors use a non-replaceable long-life battery which
requires replacement of the entire unit at the end of battery life (e.g.,
5802, 5802CP).
94
Telephone Line Failure, indicates that a monitored telephone line (if
programmed in field *92) has been cut or disconnected. Depending on how
the system was programmed, the touchpad may also produce a trouble
sound, and the external sounder may be activated. Silence by entering
installer code + OFF.
dl
If this remains displayed for more than 1 minute, the system is disabled.
NOTE for CANADIAN PANELS: Power up time is 2 minutes, and CID
code 305 System Reset is sent if the [#] + [0] command is not performed
before the 2 minutes expires.
CC
The system is in communication with the central station for change of
function or status verification.
no display
Power Failure: If there is no touchpad display at all and the LEDs are
unlit, operating power (AC and battery) for the system has stopped and
the system is inoperative.
If the message "AC LOSS" (Custom English display) or "NO AC" (English
display) is displayed, the touchpad is operating on battery power only.
If the battery standby capacity is used up during a prolonged AC power
outage, the control's power will shut down to minimize deep discharge of
the battery.
FC
A communication failure has occurred.
0C
Touchpad is not receiving signals from the control and sees an open circuit.
bF
Backup LRR communication failure.
70
Bell supervision failure.
90
RF jam detected.
00 BAT
Wireless touchpad low battery
Cd
The dialer test has been successful (CID code 601).
d0
The dialer is disabled.
dd
Walk test mode is active
dC
the upload or download session was completed
dF
the upload or download session failed before completion