3000EN SERIES: INSTALLATION INSTRUCTIONS
5800 Series Transmitter Input Loop Identification
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input
loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
LOOP
1
LOOP
1
5 8 0 0 C O
5 8 0 0 M i c r a
E N R O L L A S " R F "
E N R O L L A S " R F "
LOOP 3
LOOP 4
YOU MUST
O N
LOOP 2
O F
F
ENROLL
THIS
LOOP 1
BUTTON
LOOP
3
•
• •
•• •
• • ••
• •
•
•
5804/5804E
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
ENROLL AS "BR"
SET HOUSE ID
LOOP 2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION FOR
LOOP 2
5 8 1 6
5 8 1 6 M N
ENROLL AS "RF"
ENROLL AS "RF"
AR
M ED
RE
AD
Y
LOOPS
1 - 3
5 8 2 1
5 8 2 8 / 5 8 2 8 V
ENROLL AS "RF"
SET HOUSE ID
NOTE: For information on any transmitter not shown, refer to the instructions accompanying that transmitter for details regarding loop
numbers, etc.
UL NOTE: The following transmitters are not intended for use in UL installations:
5802, 5802MN, 5802MN2, 5804E, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.
16-2
LOOP 1
5 8 0 0 S S 1
E N RO L L A S " R F "
LOOP 2
SERIAL #1
LOOP 3
LOOP 4
SERIAL #1
YOU MUST
O N
LOOP 2
O F
F
SERIAL #1
ENROLL
1
2
LOOP 4
THIS
SERIAL #1
BUTTON
3
SERIAL #2
LOOP 1
4
LOOP 3
LOOP 1
SERIAL #2
LOOP 2
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
LOOP 4 = 3 + 4 BUTTONS
5 8 0 5 - 6
ENROLL AS "BR"
LOOP 1
(PRIMARY)
LOOP 2
LOOP 2
(REED)
(AUX.
CENTER)
LOOP 1
(TERMINALS)
LOOP 3
(AUX.
RIGHT)
5 8 1 7
ENROLL AS "RF"
SERIAL #1
SERIAL #1
SERIAL #2
LOOP
MI C
ME SS
1
AG E
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
5 8 5 3
ENROLL AS "RF"
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
5 8 0 0 WAV E
5 8 0 1
S E T H O U S E I D
E N RO L L A S
E N RO L L A S " R F "
" U R O R " R F "
LOOP 1
LOOP 1
5809
5806/5806W3
5808/5808LST/5808W3
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 2
LOOP 1
(REED)
LOOP 3
(TERMINALS)
5 8 1 8 M N L
5 8 1 9
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 3
SERIAL #1
A W
A Y
LOOP 2
S T
A Y
LOOP 4
1
2
SERIAL #1
3
LOOP 1
LOOP 3
4
SERIAL #2
LOOP 2
LOOP 4 = 3 + 4 BUTTONS
5 8 7 8
5 8 9 0 / 5 8 9 0 P I
ENROLL AS "BR"
ENROLL AS "RF"
LOOP 3
LOOP 2
LOOP 1
LOOP 1
5 8 0 2 M N
ENROLL AS
"UR" OR "RF"
LOOP 1
5814
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(INTERNAL
SHOCK
LOOP 1
SENSOR
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
LOOP 1
LOOP 1
(MOTION)
5 8 9 4 P I
ENROLL AS "RF"
LOOP 1
5 8 0 2 M N 2
ENROLL AS
"UR" OR "RF"
LOOP 2
(REED)
LOOP 1
LOOP 2
(TERMINALS)
(REED)
5 8 1 5
ENROLL AS "RF"
LOOP 1
5 8 2 0 / 5 8 2 0 L
ENROLL AS "RF"
LOOP 1
5897-35
ENROLL AS "RF"