5800 Series Transmitter Input Loop Identification - ADT Safewatch Pro 3000EN Installation And Setup Manual

Hide thumbs Also See for Safewatch Pro 3000EN:
Table of Contents

Advertisement

3000EN SERIES: INSTALLATION INSTRUCTIONS

5800 Series Transmitter Input Loop Identification

All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input
loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
LOOP
1
LOOP
1
5 8 0 0 C O
5 8 0 0 M i c r a
E N R O L L A S " R F "
E N R O L L A S " R F "
LOOP 3
LOOP 4
YOU MUST
O N
LOOP 2
O F
F
ENROLL
THIS
LOOP 1
BUTTON
LOOP
3
• •
•• •
• • ••
• •
5804/5804E
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
ENROLL AS "BR"
SET HOUSE ID
LOOP 2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION FOR
LOOP 2
5 8 1 6
5 8 1 6 M N
ENROLL AS "RF"
ENROLL AS "RF"
AR
M ED
RE
AD
Y
LOOPS
1 - 3
5 8 2 1
5 8 2 8 / 5 8 2 8 V
ENROLL AS "RF"
SET HOUSE ID
NOTE: For information on any transmitter not shown, refer to the instructions accompanying that transmitter for details regarding loop
numbers, etc.
UL NOTE: The following transmitters are not intended for use in UL installations:
5802, 5802MN, 5802MN2, 5804E, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.
16-2
LOOP 1
5 8 0 0 S S 1
E N RO L L A S " R F "
LOOP 2
SERIAL #1
LOOP 3
LOOP 4
SERIAL #1
YOU MUST
O N
LOOP 2
O F
F
SERIAL #1
ENROLL
1
2
LOOP 4
THIS
SERIAL #1
BUTTON
3
SERIAL #2
LOOP 1
4
LOOP 3
LOOP 1
SERIAL #2
LOOP 2
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
LOOP 4 = 3 + 4 BUTTONS
5 8 0 5 - 6
ENROLL AS "BR"
LOOP 1
(PRIMARY)
LOOP 2
LOOP 2
(REED)
(AUX.
CENTER)
LOOP 1
(TERMINALS)
LOOP 3
(AUX.
RIGHT)
5 8 1 7
ENROLL AS "RF"
SERIAL #1
SERIAL #1
SERIAL #2
LOOP
MI C
ME SS
1
AG E
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
5 8 5 3
ENROLL AS "RF"
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
5 8 0 0 WAV E
5 8 0 1
S E T H O U S E I D
E N RO L L A S
E N RO L L A S " R F "
" U R O R " R F "
LOOP 1
LOOP 1
5809
5806/5806W3
5808/5808LST/5808W3
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 2
LOOP 1
(REED)
LOOP 3
(TERMINALS)
5 8 1 8 M N L
5 8 1 9
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 3
SERIAL #1
A W
A Y
LOOP 2
S T
A Y
LOOP 4
1
2
SERIAL #1
3
LOOP 1
LOOP 3
4
SERIAL #2
LOOP 2
LOOP 4 = 3 + 4 BUTTONS
5 8 7 8
5 8 9 0 / 5 8 9 0 P I
ENROLL AS "BR"
ENROLL AS "RF"
LOOP 3
LOOP 2
LOOP 1
LOOP 1
5 8 0 2 M N
ENROLL AS
"UR" OR "RF"
LOOP 1
5814
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(INTERNAL
SHOCK
LOOP 1
SENSOR
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
LOOP 1
LOOP 1
(MOTION)
5 8 9 4 P I
ENROLL AS "RF"
LOOP 1
5 8 0 2 M N 2
ENROLL AS
"UR" OR "RF"
LOOP 2
(REED)
LOOP 1
LOOP 2
(TERMINALS)
(REED)
5 8 1 5
ENROLL AS "RF"
LOOP 1
5 8 2 0 / 5 8 2 0 L
ENROLL AS "RF"
LOOP 1
5897-35
ENROLL AS "RF"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterpreneur 3000enSecurity manager 3000en

Table of Contents