Placing the Boiler
6.2

Reversing the Burner Door Swing

The burner door hinges are factory installed on the right
handside the burner door swings to the right. You can
adjust the hinges so that the burner door swings to the
left in the field.
Note: the front panel must first be removed.
(
Chapter 5.1, page 13).
Remove burner door (
Remove hex head bolts of burner door hinges and re-
move hinges.
Install the hinges on the left side of the boiler with the
hex head bolts.
Remove the eyelets from the burner door by remov-
ing the hex head bolts.
Locate and secure with hex head bolts these eyelets
to the left side of the burner door.
Hang the burner door on the hinges.
Check to make sure that the flue baffle plates are
horizontally in the boiler (
Secure the burner door with the burner door bolts.
Make sure to tighten the burner door bolts evenly
with about 7.5 ft-lbs torque.
NOTICE
When reversing the swing of the burner
door, make sure to remove the burner ca-
ble and oil line from the burner first.
16
Chapter 5.1, page 13).
Chapter 8.3, page 40).
1 2
Fig. 8
Reversing burner door (boiler block)
1 Hex head bolts for hinges
2 Door hinges
3
2
1
4
Fig. 9
Reversing burner door (on burner door)
1 Hex head bolts for door eyelets
2 Door eyelet
3 Burner door
4 Door hinges
5 Flue baffles