5

Moving the Boiler

This chapter describes how to move the boiler.
SYSTEM DAMAGE
due to bumps.
CAUTION!
Protect the boiler from bumps and
rough treatment.
NOTICE
Protect the boiler from connections
from damage and dirt, when the boiler
is not installed immediately.
NOTICE
Please dispose of the packaging in an en-
vironmentally friendly fashion.
5.1

Reducing Boiler Weight for Transportation

One can reduce boiler weight by removing the front cov-
er and burner door itself.
Remove the screws holding the front cover in place.
Lift up the front cover slightly and remove.
Disconnect burner cable from burner control before
removing the burner door.
Open burner door by removing the two burner door
bolts.
Lift burner door from hinges.
NOTICE
Protect the burner door and the burner
tube from damage and dirt when the
burner door is removed from the boiler.
Logano G125 BE - Specifications subject to change without notice.
Fig. 3
Removing the front cover
Fig. 4
Removal of burner door