Xerox Phaser 6121MFP Service Manual page 134

Multi-function printer
Hide thumbs Also See for Phaser 6121MFP:
Table of Contents

Advertisement

Error Messages and Codes
3-28
Code
Possible Causes of Error
00BA
Did not receive correct signal after sending DTC signal in V.34.
00BB
DIS signal received after sending DTC in V.34.
00BC
Modem is not ready within 10 seconds after entering primary channel
in V.34.
00BD
Cannot detect correct V.21 or JM signal after detected FSK frequency.
00BE
Remote side has no document to be polled after V8 handshaking.
00BF
Capability mismatch.
00C0
Remote side disconnect before entering primary channel in V.34.
00C1
At phase D, transmitting units out EOP 3 times consecutively, but
receive no answer from receiving unit.
00C2
Remote side disconnect after sending out V.8 CM signal.
00C4
After sending MPS signal, the received signal is not one of MCF, RTN,
PIP, PIN, RTP, or DCN.
00C5
Received DCN signal after sending MPS signal.
00C9
At phase D, sending MPS 3 times consecutively, but no answer from
receiving unit.
00CA
After sending EOP signal, the received is not one of MCF, RTN, PIP,
PIN, PRI-EOP, or DCN.
00CB
After sending EOP signal, received DCN signal.
00CC
After sending EOM signal, the received signal is not one of MCF, RTN,
PIP, PIN, RTP, or DCN.
00CD
At phase D, transmitting EOM 3 times consecutively, but receive no
answer.
00CE
At phase-D, transmitting EOM, but receive DCN.
00CF
Received incorrect signal after sending DTC signal for V.34 polling.
00D0
Received ERR signal after sending EOR_NULL.
00D1
Received incorrect response after sending PPS_EOP signal in V.34.
00D2
Received DCN after sending PPS_EOP signal.
00D3
Received DCN after sending PPS_NULL signal.
00D4
Received DCN after sending PPS_EOM signal.
00D8
Cannot detect correct phase 3 signal for polling within 25 seconds.
00D9
Cannot detect correct phase 3 signal after detect silence after
phase 2.
00DA
Can not detect phase 4 signal within 30 seconds or remote side hang
up over 6 seconds.
00DB
Cannot detect any T.30 signal within 15 seconds during phase 4.
00DC
Received T.30 signal in phase 4 other than DCS, DIS or DTC.
00DE
Remote side no SUB capability in V.34.
00E0
At phase-D, transmitting PPS_NULL 3 times consecutively but receive
no answer.
Phaser 6121MFP Service Manual