E-Mail Alert Program Installation

Configuring Alarm and E-Mail Notification Over TCP/IP

Rev 1.00
This appendix describes the Honeywell E-Mail Net monitoring utility used for alarm and
e-mail notification over TCP/IP.
The HRDV can be configured to forward up to 12 different alarm conditions via TCP/IP to
a remote monitoring program and to notify up to five e-mail addresses. When the HRDV
detects a notification condition defined by a user, the condition is forwarded over TCP/IP
network to the monitoring utility provided by Honeywell. The monitoring utility interfaces
with the customer's e-mail system to notify of these conditions (up to five different e-mail
addresses). The HRDV will also log the messages in a log file. You can also attach an
image of the event from a camera, provided this feature is enabled.
Requirements:
The HRDV unit:
Must have an Ethernet PCMCIA card installed
Be enabled for remote access via Ethernet (see
Ethernet)
Be connected to a network
The customer must have a PC with an e-mail service installed.
The Honeywell monitoring (E-Mail Alert) program must be installed on a customer's
networked PC.
The subsection that follows describes how to configure the HRDV for alarm and e-mail
notification over Ethernet. To install and configure the E-Mail Alert program, see
the E-Mail Alert
Program, page 167.
1.
From the Remote Access screen, select Advanced Setup (see
the Advanced Remote Setup screen, highlight Setup Email and press Enter to
open the Setup Email Screen. Alarm Notification must be enabled to be able to
open the Setup Email screen.
2.
Configure the Advanced Remote Setup and the Setup Email screens as described
in
Table
A-1.
165
A
Chapter 19, Networking on
Installing
Figure
A-1). From
Document 900.0261
04/05