(13) Removal of the Ozone Filter (PC Drum Charge Corona)
(14) Removal of the Ozone Filter (Image Transfer/Paper Separator Coronas)
(15) Removal of the Toner Collecting Bottle
3. Using a soft cloth dampened with alcohol, wipe
clean the Main Erase Lamp Filter.
1136D187AA
1. Swing down the Front Door.
2. Swing out the Main Hopper.
3. Slide out the Ozone Filter.
4002D143AB
1. Unhook one tab and remove the Filter Cover.
2. Pull out the Ozone Filter.
4002D144AB
1. Slide out the drawers from the applicable paper
source option.
(There is no need of sliding out the drawer for
LCC.)
2. Swing down the Toner Collecting Bottle Cover.
3. Remove the Toner Collecting Bottle.
NOTE
4640U006AA
When the Toner Collecting Bottle has been replaced,
clear the "Waste Toner-Count" count of "Consumables"
available from "Counter" under the Tech. Rep. mode.