12. Call the Adjust mode to the screen.
13. Touch [IR].
14. Touch [Zoom (CD)].
15. Press the Clear key to clear the current
setting value.
16. Use the 10-key pad to change the setting
value.
Setting Instructions
If width A on the test pattern copy is greater than that on the original test pattern, decrease
the setting value.
If width A on the test pattern copy is smaller than that on the original test pattern, increase
the setting value.
17. Touch [END] to validate the setting value.
18. Go back to the Basic screen.
19. Perform steps 9 and 10.
20. Check for any difference in width A between the original test pattern and the test pattern
copy.
If there is any difference, try another setting value for rechecking.
Use to clear the
setting value.
Use to enter the
setting value.
Setting Value