10. Call the Adjust mode to the screen.
11. Touch [IR].
12. Touch [Scale (CD)].
13. Press the Clear key to clear the current
setting value.
14. Use the 10-key pad to change the setting
value.
NOTE
Use the Access key to select the sign of
+ or -.
Setting Instructions
If the position of the leading edge of the scale reproduced on the enlarged copy deviates
from that on the full-size copy, decrease the setting value.
If the leading edge of the scale is not reproduced on the full-size copy, increase the setting
value.
15. Go back to the Basic screen.
16. Perform steps 5 through 9.
17. Check to see if conditions of steps 8 and 9 are met.
If the conditions are not met, try another setting value for rechecking.
18. If the conditions are met, return Registration (CD) and Erasure Width to the values
recorded.
Use to clear the
setting value.
Use to enter the
setting value.
Setting Value
D-100
3
4
5
6
7
8
9
0
C
Use to change the
+ or - sign.