Removing The Try Select Switch Board; Removing The Cam Unit - JVC MX-G950V Service Manual

Compact component system
Hide thumbs Also See for MX-G950V:
Table of Contents

Advertisement

MX-G950V/MX-G880V
MX-G850V/MX-G750V

Removing the try select switch board

1.
Remove the two screws G retaining the tray select
switch board.
2.
Disconnect the tray select switch board from connector
CN804 on the CD servo control board.

Removing the cam unit

1.
Remove the CD loading mechanism assembly.
2.
While turning the cam gear "q", align the Paul "r"
position of the drive unit to the notch position(Fig.16) on
the cam gear "q".
3.
Pull out the drive unit and cylinder gear(See Fig.17).
4.
While turning the cam gear "q", align the Paul "s"
position of the select lever to the notch position(Fig.18)
on the cam gear "q".
5.
Remove the four screws H retaining the cam unit(cam
gear "q" and cams R1/R2 assembly)(See Fig.18).
1-22
(See Fig.14)
(See Fig.15 ~17 )
Drive unit
Cylinder gear
Fig.16
Chassis assembly
CN854
CN851
Fig.14
Drive unit
r
Fig.15
H
Cams R1, R2 assembly
q
Cam gear
H
s
Select lever
Fig.17
Tray select
switch board
G
CN804
q
Cam gear
Cam unit
J