Step
Action
Increment the Gain
Number by one and
then press ENTER.
12
Record the TOF Value.
Repeat this process for
each Gain Number.
Gain Number
00
01
02
...
31
Step
Action
Calculate the best Gain
Setting. In your sample
calibration table. Where
both the Label Value
and TOF Value are at
least 20, subtract the
amounts and record
the result as a
13
Difference Value (see
below).
Identify the largest
Difference Value and its
corresponding Gain
Number. This Gain
Number will be used to
resample the media.
Gain Number
00
01
02
...
15
16
17
18
19
...
31
(continued)
Adjustments and Maintenance
Displayed Message
TRAN SENSOR GAIN
yyy
(0 - 31)
Sample Calibration Table
Label Value
TOF Value
252
250
248
...
09
Displayed Message
TRAN SENSOR GAIN
yyy
(0 - 31)
Sample Calibration Table
Label Value
TOF Value
252
250
248
...
188
184
179
174
170
...
132
2-18
Comment
Remaining TOF Values, where
"yyy" represents the current
sensor reading.
01
Difference Value
248
245
234
...
14
Comment
In this example, Gain Number
18 is chosen because, where
both values are at least
twenty, it has the highest
31
Difference Value.
Difference Value
248
4
245
5
234
14
...
...
63
125
51
133
38
141
25
149
19
N/A
...
...
14
N/A