Step
Action
Raise the printhead
assembly then proceed
according to the media
type:
Die-cut: Peel labels
•
from the backing
then insert the
backing under the
10
Sensor Eye Mark;
Notched: Insert the
•
notch under the
Sensor Eye Mark; or,
Reflective: Insert the
•
black mark facedown
under the Sensor
Eye Mark.
Lower and latch the
printhead assembly.
Set the Gain Number to
00 and then press
11
ENTER.
Record the reading as a
TOF Value for Gain
Number 00 in the table.
Gain Number
00
01
02
...
31
(continued)
Adjustments and Maintenance
Displayed Message
TRAN SENSOR GAIN
yyy
(0 - 31)
TRAN SENSOR GAIN
yyy
(0 - 31)
Sample Calibration Table
Label Value
TOF Value
252
250
248
...
09
2-17
Comment
Do not position a perforation
in the Media Sensor; and if
using preprinted media,
ensure the label area placed
in the sensor is free of text,
31
graphics, lines, etc.
This is the TOF Value for a
gain setting of 00, where
"yyy" represents the current
sensor reading.
00
Difference Value
248