Table 6-36
SM Locations of the PTO / PWM Control Registers
Q0.0
Q0.1
Status Bits
SM66.4
SM76.4
PTO profile aborted (delta calculation error): 0 = no error
SM66.5
SM76.5
PTO profile aborted due to user command: 0 = no abort
SM66.6
SM76.6
PTO/PWM pipeline overflow/underflow:
SM66.7
SM76.7
PTO idle:
Q0.0
Q0.1
Control Bits
SM67.0
SM77.0
PTO/PWM update the cycle time:
SM67.1
SM77.1
PWM update the pulse width time:
SM67.2
SM77.2
PTO update the pulse count value:
SM67.3
SM77.3
PTO/PWM time base:
SM67.4
SM77.4
PWM update method:
SM67.5
SM77.5
PTO single/multiple segment operation:
SM67.6
SM77.6
PTO/PWM mode select:
SM67.7
SM77.7
PTO/PWM enable:
Q0.0
Q0.1
Other PTO/PWM Registers
SMW68
SMW78
PTO/PWM cycle time value
SMW70
SMW80
PWM pulse width value
SMD72
SMD82
PTO pulse count value
SMB166
SMB176
Number of the segment in progress
SMW168
SMW178
Starting location of the profile table
(byte offset from V0 )
SMB170
SMB180
Linear profile status byte
SMB171
SMB181
Linear profile result register
SMD172
SMD182
Manual mode frequency register
Table 6-37
PTO/PWM Control Byte Reference
Result of Executing the PLS Instruction
Control
Control
Register
Select
(Hex
Enable
Mode
Value)
16#81
Yes
PTO
16#84
Yes
PTO
16#85
Yes
PTO
16#89
Yes
PTO
16#8C
Yes
PTO
16#8D
Yes
PTO
16#A0
Yes
PTO
16#A8
Yes
PTO
16#D1
Yes
PWM
16#D2
Yes
PWM
16#D3
Yes
PWM
16#D9
Yes
PWM
16#DA
Yes
PWM
16#DB
Yes
PWM
PTO
PWM
Segment
Update
Operation
Method
Single
Single
Single
Single
Single
Single
Multiple
Multiple
Synchronous
Synchronous
Synchronous
Synchronous
Synchronous
Synchronous
S7-200 Instruction Set
1 = aborted
1 = aborted
0 = no overflow
1 = overflow/underflow
0 = in progress
1 = PTO idle
0 = no update
1 = update cycle time
0 = no update
1 = update pulse width
0 = no update
1 = update pulse
0 = 1 µs/tick
1 = 1 ms/tick
0 =asynchronous 1 = synchronous
0 = single
1 = multiple
0 = PTO
1 = PWM
0 = disable
1 = enable
range: 2 to 65,535
range: 0 to 65,535
range: 1 to 4,294,967,295
Multiple-segment PTO operation only
Multiple-segment PTO operation only
Pulse
Pulse
Time Base
Count
Width
1 µs/cycle
1 µs/cycle
Load
1 µs/cycle
Load
1 ms/cycle
1 ms/cycle
Load
1 ms/cycle
Load
1 µs/cycle
1 ms/cycle
1 µs/cycle
1 µs/cycle
Load
1 µs/cycle
Load
1 ms/cycle
1 ms/cycle
Load
1 ms/cycle
Load
Chapter 6
count
Cycle
Time
Load
Load
Load
Load
Load
Load
Load
Load
137