CHAPTER 6
Installing the SRX5600 Services Gateway
Mounting Hardware
Installing the SRX5600 Services Gateway Mounting Hardware for a Rack or Cabinet
Copyright © 2014, Juniper Networks, Inc.
Installing the SRX5600 Services Gateway Mounting Hardware for a Rack or
Cabinet on page 55
Moving the Mounting Brackets for Center-Mounting the SRX5600 Services
Gateway on page 57
The services gateway can be installed in a four-post rack or cabinet or an open-frame
rack. Install the mounting hardware on the rack before installing the services gateway.
NOTE:
An optional air deflector kit is available that lets you install the
SRX5600 Services Gateway in a hot aisle/cold aisle ventilation environment.
If you use this air deflector kit, you do not need to install the mounting shelf
as described in this section. For more information about the hot aisle/cold
aisle air deflector kit, send an e-mail to
Install the mounting shelf, which is included in the shipping container, before installing
the services gateway. We recommend that you install the mounting shelf because the
weight of a fully loaded chassis can be up to 220 lb (100 kg).
Table 20 on page 55
specifies the holes in which you insert cage nuts and screws to install
the mounting hardware required. The hole distances are relative to one of the standard
U divisions on the rack. The bottom of all mounting shelves is at 0.02 in. above a U division.
Table 20: Four-Post Rack or Cabinet Mounting Hole Locations
Hole
Distance Above U Division
3
1.51 in. (3.8 cm)
2
0.88 in. (2.2 cm)
1
0.25 in. (0.6 cm)
DL-Air-Deflectors@juniper.net
0.86 U
0.50 U
0.14 U
.
55