of battery B2.
4. Connect the positive (red) terminals of the batteries as described below (and shown in the
figure below). Note that there may be a small amount of electrical arcing when electrical
contact is made.
a. Connect the middle connector of the red wire to the positive (red) terminal of battery
B1.
b. If required, connect the end connector of the red wire to the positive (red) terminal of
battery B2.
5. Close the unit and secure it with the four screws.
6. Stick a label on the unit stating the date of the installation and the number of batteries
installed.

Connecting to the OmniPCX Office RCE Compact Platform

1. Switch off the Alcatel-Lucent OmniPCX Office Communication Server system and then:
a. Unplug the power cable from the mains socket.
b. Disconnect the mains adapter from the OmniPCX Office RCE Compact platform.
c. Using a screwdriver, unscrew the power supply module (PSXS or PSXS-N) from the
side of the OmniPCX Office RCE Compact platform and pull the module out of the
cabinet.
2. Move the red extBAT jumper from the NO position to the YES position.