9.19
Fuser Unit
(1) Release the harness of the fuser unit from the guides of the main frame R ASSY.
(2) Disconnect the connector of the low voltage power supply PCB ASSY while pushing the
hook of the connector of the fuser unit.
Main frame R ASSY
Connector
(low voltage power
supply PCB ASSY)
(3) Put the connector of the fuser unit through the hole of the main frame R ASSY.
Connector
(low voltage power
supply PCB ASSY)
Hook
Fig. 3-65
Fig. 3-66
3-80
Guides
Connector (fuser unit)
Connector (fuser unit)
Hole
Connector (fuser unit)
Guide
Confidential