■ Error code C1 to C6
These errors do not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
Error, which cannot be specified, occurs.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
1
Main PCB failure
■ Error code C7
Out of Memory
Press Job Cancel.
Insufficient memory.
<User Check>
• Delete the stored data.
Step
1
Main PCB failure
■ Error code C8
Out of Memory
Secure Print Data is full. Press Job Cancel and delete the
previously stored data.
RAM area for secure data full.
<User Check>
• Delete the stored data.
Step
1
Main PCB failure
Cause
Cause
Cause
2-63
Remedy
Replace the main PCB ASSY.
Remedy
Replace the main PCB ASSY.
Remedy
Replace the main PCB ASSY.