7.0 Power Requirements - Jacuzzi J - 400 SERIES J - 460 Owner's Manual

J-400 series
Table of Contents

Advertisement

J-400 Series
Figure-C
RED
1
BLK
2
Green
all north american 240V models:
240 VAC, 3-Wire Connection 60 Hz

7.0 Power requirements

Jacuzzi® spas are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
They are configured at the factory. The most common electrical
connections are listed below:
All North American 60Hz Models: 240VAC/50A**
All Export 50Hz Models: 230VAC/30A**
If you prefer, your qualified technician can perform a minor circuit board
modification that allows the hot tub to operate on a different electrical
service (see table footnotes below).
North American J-460/J-465/J-470/J-480 Models (60Hz)
Voltage:
Max. Current Draw:
Frequency:
Number of Wires:
Circuit Breaker (2-Pole):
In 30A configuration, the heater will not operate while either jets
*
pump is running.
** In 50A configuration, the heater will not operate while both jets
pumps are running. This is the factory setting.
*** In 60A configuration the heater will operate while both jets pumps
are running.
Page 14
RED
TB1
RED
BLK
BLK
to Circuit
Board
TB3
240 VAC
23A
60 Hz
30A*
Figure-D
all export models:
230 VAC, 3-Wire Connection 50 Hz
240 VAC
36A
60 Hz
3
3
50A**
BLUE
TB1
BLUE
1
BROWN
BROWN
2
to Circuit
Green
Board
TB3
240 VAC
45A
60 Hz
3
60A***

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-460J-465J-470J-480