2. Firmly tighten the bolt. 
NOTE: Handle should spin freely with minimal play. If handle does not spin freely make sure the 
spacer is firmly in place. If handle still does not spin freely, contact Invacare.
Bolt
Crankarm
FIGURE 9.10 Installing V/S Crankarm Handles - For Models Made Before 7/12/07

For Models Made After 7/12/07

WARNING
Failure to install handle assembly
properly could result in injury.
It is recommended to inspect this
assembly prior to and after each use.
NOTE: For this procedure, refer to 
FIGURE 9.11.
1. Secure the handle to the crankarm 
housing using the set screw and 
locknut.
NOTE: Use the right handle, the handle with a 
mounting post, with the right crankarm and 
left with left crankarm. The right crankarm has 
a flange at the base of the crankarm. The left 
crankarm does not.
2. Firmly tighten the locknut. 
NOTE: Handle should spin freely with 
minimal play. If handle does not spin freely, 
contact Invacare.
Part No 1114850
Bearing
Spacer
Handle
65
SECTION 9—OPTIONS
Crankarm
Housing
Bearing
DETAIL "A" - HANDLE
Set
Screw
Handle
Crankarm
DETAIL "B" - CRANKARM
ORIENTATION
Left
Flange
Left
Crankarm
FIGURE 9.11 Installing V/S Crankarm
Handles - For Models Made After 7/12/07
Recumbent Handcycle Series
Handle
REPLACEMENT
Crankarm Housing
Locknut
Mounting
Post
Right
Handle
Right
Crankarm