Leveling; Gas Connections - Vulcan-Hart GH30 Installation & Operation Manual

Gh series heavy duty gas ranges
Table of Contents

Advertisement

LEVELING

Unlevel range(s) will create battery installation problems in lining up the manifolding system, and result
in uneven cooked product. Using a carpenter's level, level the range(s) from front-to-rear and side-to-
side. With range in its exact location or battery position, adjust leg heights. If installing a battery of
equipment, begin with first unit in battery lineup. Adjust legs by turning feet until all legs are resting on
the floor. If "less legs base" or "toe base" is used, screw the leveling bolt until floor contact is made.
(Fig. 18)
PL-40051
Fig. 18
The casters provided for the ranges are the non-leveling type; therefore the floor must be reasonably
level or baked products will be uneven and performance will be inconsistent.

GAS CONNECTIONS

CAUTION: All gas supply connections and any pipe joint compound used must be resistant to
the action of propane gases.
Remove oven bottom(s) and baffles.
Remove upper manifold panel(s).
Connect gas supply to the range(s). Make sure the pipes are clean and free of obstructions, dirt, and
piping compound.
Codes require that a gas shutoff valve be installed in the gas line ahead of the range(s).
Ranges manufactured for use with propane gas are equipped with fixed orifices.