4. If pilot fails to light, turn main gas valve OFF. Wait 5 minutes and repeat Steps 2 and 3.
5. After pilot is lit, push the power switch ON and turn the temperature dial to the desired setting.
Nightly Shutdown: Turn power switch OFF and the temperature dial to 0 degrees.
Complete Shutdown:
1. Push power switch OFF.
2. Turn red gas valve (located behind the control panel) OFF.
3. Turn main gas supply OFF.
4. Disconnect electrical supply cord.

ADJUSTMENTS

All adjustment procedures associated with pilot lighting should be performed by an authorized
Vulcan-Hart installation or service person. The bypass (minimum burner) flame adjustment must
be made at the time the range is installed.
After adjustments are complete, replace oven control panel(s). Check identification so that each panel
is returned to its respective range. Replace oven baffles and oven bottom(s).
Replace upper manifold panel(s). Position brick in ranges where necessary (Fig. 20). Replace top
casting(s). Check identification so that each may be returned to its respective original range as
received from the factory.
Fig. 20