ELECTRIC EXPANDO RANGES
Before installing, verify that the electrical service
agrees with the specifications on the data plate
located below the control panel. If the supply
and equipment requirements do not agree,
contact your dealer or Vulcan-Hart immediately.

UNPACKING

Immediately after unpacking, check for possible
shipping damage. If the range is found to be
damaged, save the packaging material and
contact the carrier within 15 days of delivery.
Remove all shipping wire, wood blocking and
accessories.
INSTALLATION CODES
AND STANDARDS
In the United States, the Vulcan range must be
installed in accordance with:
1. State and local codes.
2. National Electrical Code (ANSI/NFPA No.70,
latest edition) available from the National
Fire Protection Association, Batterymarch
Park, Quincy, MA 02269.
3. Vapor Removal from Cooking Equipment,
(NFPA-96, latest edition) available from NFPA.
In Canada, the Vulcan range must be installed in
accordance with:
1. Local codes.
2. Canadian Electrical Code (CSA C22.2 No.3,
latest edition) available from the Canadian
Standards Association, 5060 Spectrum
Way, Mississauga, Ontario, Canada L4W 5N6.

LOCATION

The installation location must allow adequate
clearance for servicing and proper operation. A
minimum front clearance of 40" (1016 mm) is
required. 0" sides and rear clearance from

INSTALLATION

combustible and non-combustible construction
is required except when Hot Top sections are
incorporated. Ranges incorporating Hot Top
sections require a 0" sides and rear clearance
from non-combustible construction and 6" from
combustible construction.
Place a carpenter's level on top of the range and
level the range front-to-back and side-to-side by
turning the adjustable feet.
WARNING: ELECTRICAL AND
WARNING: DISCONNECT THE
Position the range in its final location. Bring
conduit containing the proper supply wire to the
range through the knockout located on the
bottom right front of the range. Select the size
and type of field wire in accordance with the
National Electrical Code suitable for carrying
the equipment's rated amps and voltage.
Connect supply leads to field terminal block and
green grounding lead to the labeled ground lug.
E12FP ranges wired for 3-phase service may
be changed to 1-phase, or vice versa. Refer to
the wiring diagram and schematic decal attached
to the range. E12HT ranges are not convertable;
they are only available in a single phase
configuration.
— 6 —

LEVELING

ELECTRICAL CONNECTIONS

GROUNDING CONNECTIONS
MUST COMPLY WITH
APPLICABLE PORTIONS OF
THE NATIONAL ELECTRICAL
CODE AND / OR OTHER
LOCAL ELECTRICAL CODES.
ELECTRICAL POWER TO
THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT
PROCEDURES.