Rear Vent Configurations with Horizontal Termination and 1' Min. Rise

Use 6-5/8" Diameter Vent
Horizontal sections require a ¼" (6mm) rise every 12" (305mm) of travel.
Maximum of one (1) 45° or 90° horizontal elbow may be used (see illustration).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may
vary slightly, especially when the termination is near a demarcation line.
Diffuser set to open (stock) position).
Do not install the intake damper plate or exhaust restrictor extender plates.