Heater Placement Requirements
•
Heater must be installed on a level surface capable of supporting the heater and vent
•
Due to the high temperature, the heater should be located out of traffic and away from furniture and
draperies.
•
When placed in a location where the floor to ceiling height is under 7 feet, the installation is
considered an alcove and must meet the following requirements:
-
The alcove floor to ceiling height must be at least 38-1/8" (968mm) tall
The alcove must not be more than 24" (610mm) deep before the ceiling returns to 7' (2134mm)
-
-
The alcove must be at least 28-1/4" (718mm) wide
•
The heater must not be placed so the vents below or above the door, along the sides of heater, or
along the back of the heater can become blocked.
•
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
Floor Protection Requirements
•
When the stove is installed directly on carpeting,
vinyl or other combustible material other than
wood flooring or a high pressure laminate wood
floor, the stove must be installed on a metal or
wood protection panel extending the full width
and depth of the heater (Minimum 21-1/4" wide
by 15-7/8" deep).
Electrical Requirements
•
Plug the stove into a grounded receptacle supplying a minimum 1.5 amps (120 Volts, 60 Hz, 180
watts).