Travis Industries Northfield GS2 Owner's Manual page 46

Lopi direct vent freestanding stove, natural gas or propane, vent horizontally or vertically, standard residential, mobile home approved
Table of Contents

Advertisement

Optional Equipment
46
4
Install the LP pilot orifice following the instructions below.
(a) Use a 7/16" open-end wrench to remove the pilot hood.
(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace
the pilot hood, tightening the pilot hood until it is snug (do not over-tighten).
5
Replace the firebox components. Install the logs
and embers. Replace the glass.
6
Remove and discard the screws (see "a" below)
holding the stock regulator in place (see "b" below).
Remove the stock regulator and gasket (see "c"
below). Place the LP regulator in place, making sure
the pre-fitted gasket (see "c" below) is in place.
NOTE: There is a label on the base of the regulator
knob indicating regulator type (NG or LP). Secure
the regulator with the screws included with the
regulator – tighten to 25 lb-in of torque. Place the
included label on the valve body where it can be
easily seen to insure proper identification.
NOTE: Leak test this area after the heater is
installed, gas is connected, and the main burner
is lit.
7
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas
connections and the gas control valve.
© Travis Industries
Natural Gas Orifice = .020N (3way)
LP (Propane) Orifce = .014LP
a
7/16" Wrench
(for qualified installers only)
.020N
or
.018N (2way)
.018N
.014LP
a
b
d
4121120
b
T-20 Torx or
Slotted Screwdriver
c
100-01315