3. ADJUSTMENTS
Using sentences selected on other control unit
You can use the display settings selected on other control unit.
1. Open the SYSTEM SETUP menu.
2. Rotate the course control knob to select "RECEIVE SCREN SETUP NO".
3. Press the course control knob to show the optional window.
4. Rotate the course control knob to select the control unit No. from which you want to
copy settings.
5. Press the course control knob.
Confirming the input sentences
The INCOMING NMEA0183 DATA window shows the current input sentences.
1. Open the SYSTEM SETUP menu.
2. Rotate the course control knob to select "INCOMING NMEA0183 DATA".
3. Press the course control knob to show the INCOMING NMEA0183 DATA window.
4. Confirm the current input sentences (in reverse video).
5. Press the TURN/MENU key to close the window.
3.6.3 Setting the function of DODGE keys
You can select the degree which is changed when ◄ or ► key is pressed, among from 5,
10 or 20°.
1. Open the SYSTEM SETUP menu.
2. Rotate the course control knob to select ◄ ► KEY MODE.
3. Push the course control knob to select the setting among from DODGE, +/-5°, +/-10°
and +/-20°.
4. Press the course control knob to set.
3-24
INCOMING NMEA0183 DATA
Current
AAM
BWR
input
APA
DBT
sentence
APB
DPT
BOD
GGA
BWC
GLC
PUSH MENU KEY TO RETURN
TO PREVIOUS MENU.
Incoming NMEA0183 data window
GCC
HDM
RMC
VWT
GNS
MTW
VBW
WPL
GTD
MWV
VHW
XTE
HDG
RMA
VYG
ZDA
HDT
RMB
VWR

Hide quick links: