Caution: If these wires are not connected properly, you will send (+) 12 volts
directly to (-) ground, possibly damaging the alarm or the factory switch.
Type D: Adding one or more aftermarket actuators
In order for this system to control one or more aftermarket actuators, a DEI 451M
(not included) or two relays are required. Vehicles without factory power door
locks require the installation of one actuator per door. This requires mounting the
door lock actuator inside the door.
Other vehicles may only require one actuator installed in the driver's door, if all
door locks are operated when the driver's lock is used. The fuse used on 12 volt
inputs should be 7.5A per motor installed in the vehicle.
Important: Do not connect the outputs of the alarm directly to the actuator.
GREEN
BLUE
Note: Directed Electronics offers an adaptor (P/N 524T) for cars that have cable
driven doors.