4.14.2 Ribbon Take-Up Hub & Clutch Assembly - Datamax I-Class Mark II Maintenance Manual

Hide thumbs Also See for I-Class Mark II:
Table of Contents

Advertisement

I-Class Mark II Maintenance Manual
Removal and Replacement
4.14.2 Ribbon Take-up Hub & Clutch Assembly
Removal:
1. Remove the Thermal Transfer Assembly; see Section 4.14.
2. Remove the E-Ring from the Take-Up Hub shaft and then remove the Inner Bearing.
3. Remove the Take-Up Hub and the Outer Bearing from the Thermal Transfer Housing.
4. Slightly compress the Take-Up Hub Clutch then remove it from the Thermal Transfer Housing.
Replacement:
1. Reinstall the Outer Bearing in the Thermal Transfer Housing.
2. Position the Take-Up Hub Clutch in the Thermal Transfer Housing
3. Slide the Take-Up Hub shaft through the Take-Up Hub Clutch and Thermal Transfer Housing.
4. Reinstall the Inner Bearing and clip the E-Ring onto the Take-Up Hub shaft.
5. Reinstall the Thermal Transfer Assembly; see Section 4.14.
68