Fault Diagnosis - Mira Vie Installation And User Manual

Electric shower
Hide thumbs Also See for Vie:
Table of Contents

Advertisement

The troubleshooting information tabled below gives you details on probable causes
and remedies should difficulties be encountered whilst the shower is in operation.
Warning! There are no user serviceable components beneath the cover of the
appliance.
Only a competent tradesperson should remove the FRONT cover!
Malfunction
Shower is too hot
during the summer.
Shower is too hot.
Turning the
temperature knob
does not affect the
water temperature.
The water continues
to flow when the
double pole switch
is turned off.
No water or very low
flow rate.

FAULT DIAGNOSIS

Cause
The incoming water is
warmer in the summer, so
the shower power setting is
too high.
The handset sprayplate is
blocked.
The handset sprayplate is
blocked.
Broken diaphragm.
The handset sprayplate is
blocked.
The incoming water
supply stop valves, or the
appliance isolating valve, is
closed.
The hose or handset is
blocked.
The power is off at the
double pole switch.
The fuse is blown or the
MCB/RCD has been
tripped, indicating a
possible electrical fault.
Turn the power knob to Eco and
adjust the temperature knob until
the desired temperature is reached.
Regularly clean the handset
sprayplate.
Remove and clean the handset
sprayplate. If the fault persists,
contact the shower installer.
Contact your installer to replace the
flow valve assembly.
Clean the handset sprayplate.
Open the stop/isolating valve
completely.
Clear the blockage or replace the
hose or handset.
Switch on the power at the double
pole switch.
Renew the fuse or reset the MCB/
RCD. If the fault persists, contact
the shower installer.
21
Remedy
(continued)