Mira Virtue Installation & User Manual

Thermostatic mixer

Advertisement

Quick Links

Mira Virtue
Thermostatic Mixer
These instructions must be left with the user
Installation & User Guide
1
1350004-W2-A

Advertisement

Table of Contents
loading

Summary of Contents for Mira Virtue

  • Page 1 Mira Virtue Thermostatic Mixer These instructions must be left with the user Installation & User Guide 1350004-W2-A...
  • Page 2: Important Safety Information

    Important Safety Information Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided: 1. They are installed, commissioned, operated and maintained in accordance with manufacturer’s recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order.
  • Page 3 Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. The Mira Virtue thermostatic mixer is a thermostatic shower control with a single control lever for on/off and temperature control. A 12 L/Min flow regulator is supplied for high pressure systems to reduce excessive shower force. The thermostatic mixer incorporates a wax capsule temperature sensing unit, which provides an almost immediate response to changes in pressures or temperature of the incoming water supplies to maintain the selected temperature.
  • Page 4: Recommended Usage

    Recommended Usage Recommended Usage  Domestic  Light Commercial  Heavy Commercial Healthcare  Patents and Design Registration 2 291 693, 2 392 225, 2 422 886 Euro: 1 672 257 DE FR GB IT NL SE USA: 7 240 850 Patent Applications: Euro: 07015846.4 USA: 2006-0124758-A1, 2010-0219255-A1 1353004-W2-A...
  • Page 5: Pack Contents

    Pack Contents Tick the appropriate boxes to familiarise yourself with the part names and to confirm that all of the parts are included. Mira Virtue 4 x Compression Nuts (18 mm) 1 x Wall Bracket 4 x Olives (18 mm) 1 x Shower Arm 2 x Compression Nuts (15 mm) 1 x Rigid Riser 2 x Olives (15 mm) 5 x Wall Plugs 1 x Deluge Head 3 x Fixing Screws (Chrome - Wall Bracket) 2 x Fixing Screws 2 x Concealing Plates 1 x Thermostatic Mixing Valve 1 x Flow Regulator &...
  • Page 6 Mira Virtue with Diverter 1 x Wall Bracket 1 x Showerhead 6 x Compression Nuts (18 mm) 2 x Hose Washers 1 x Shower Arm 6 x Olives (18 mm) 1 x Rigid Riser (Long) 2 x Compression Nuts (15 mm) 2 x Olives (15 mm) 1 x Deluge Head 5 x Wall Plugs 3 x Fixing Screws (Chrome - Wall Bracket) 1 x Diverter Valve...
  • Page 7: Specifications

    Specifications Pressures • Max Static Pressure: 10 Bar. • Max Maintained Pressure: 5 Bar. • Min Maintained Pressure (Gravity System): 0.1 Bar (0.1 bar = 1 Metre head from cold tank base to showerhead outlet). Note! For gravity fed or other low pressure systems (0.5 bar or below) do not fit the outlet flow regulator. • For optimum performance supplies should be nominally equal. Temperatures • Factory Pre-set at safe temperature under ideal inlet supply conditions. See ‘Commissioning’.
  • Page 8 Dimensions Mira Virtue 1050 1050 Mira Virtue with Diverter 1006 1006 All dimensions in mm 1353004-W2-A...
  • Page 9: Installation

    Installation Suitable Plumbing Systems Gravity Fed: The thermostatic mixer must be fed from a cold water cistern (usually fitted in the loft space) and a hot water cylinder (usually fitted in the airing cupboard) providing nominally equal pressures. Mains Pressurised Instantaneous Hot Water System (Combination Boiler): The thermostatic mixer can be installed with systems of this type with balanced pressures. (Recommended Minimum Maintained Pressure: 1.0 Bar). There is no flow adjustment with this product. A 12 l/min flow regulator is supplied and is recommended to be fitted in High Pressure systems(see Flow Regulator Installation) Unvented Mains Pressure System:...
  • Page 10 Decide on a suitable position for the Mixer. The position of the Mixer and the Shower Fittings must provide a minimum gap of 25 mm between the spill-over level of the shower tray/bath and the showerhead (refer to illustration). This is to prevent back-siphonage. For further information on the installation of your Shower Fittings, refer to the Fittings Installation and User Guide. Note! Only use Shower Fittings recommended by the manufacturer or supplier.
  • Page 11 For rising or falling supplies the pipe Note! The Mira Virtue with Diverter positions should be set 35 mm from cannot be installed with a falling the centre of pipe to the finished wall at supply.
  • Page 12 Ø  6   m m drill required for wall plugs supplied For solid walls, drill the holes for the backplate with a 6 mm drill and insert the wall plugs. Note! For other types of wall structure alternative fixings may be required (not supplied). DO NOT drill through the backplate into the wall. DO NOT drill into buried cables or pipes. Backplate Remove the backplate from the mixer by loosening the grubscrew with a 2.5 mm hexagonal key. 1353004-W2-A...
  • Page 13 FALLING SUPPLIES REAR SUPPLIES For Rear Entry Supplies Only: Note! Falling supplies are not suitable for Mira Virtue with diverter. Fit the concealing plates over the inlet pipes. Note! Apply silicone sealant to the back face of the concealing plate. Flush the water supplies thoroughly before connecting the shower unit.
  • Page 14 Fit the shower unit over the backplate and fix to the pipework. Avoid damage to the chrome finish when tightening the compression nuts. Tighten the grubscrew to secure the mixer to the backplate. DO NOT overtighten the screw. 1353004-W2-A...
  • Page 15 Installation of Shower Fitting A. Mira Virtue Flow Regulator Wall Bracket Adapter Horizontal Rigid Riser Pipe Showerhead 1. Temporarily fit the rigid riser pipe and wall bracket to the shower control outlet and mark the position of the wall bracket. Use a spirit level to ensure the pipe is vertical. Drill the holes and insert the wall plugs. Note! The vertical rigid riser pipe can be shortened if required. De-burr the pipe ends before making the final connection.
  • Page 16 B. Mira Virtue with Diverter Refer to ‘Mira Virtue, paragraphs 1 to 9’ to install the mixer. Wall Bracket Horizontal Arm Showerhead Rigid Riser Pipe (long) Showerhead Parking Socket Sleeve Parking Socket Diverter Shower Hose Adapter Flow Regulator Rigid Riser Pipe (short) 2. Temporarily fit the rigid riser pipe (short), diverter, rigid riser pipe (long) and wall bracket to the shower control outlet and mark the position of the wall bracket.
  • Page 17: Reversed Inlet Supplies

    11. Before using the shower, refer to section: ‘Commissioning’. Reversed Inlet Supplies The Mira Virtue thermostatic mixer is supplied with inlet connections Hot - Left, Cold - Right as standard. If the hot and cold water supply pipes have been reversed during installation the thermostatic cartridge must be removed and rotated 180°.
  • Page 18 ‘O’ Key Cartridge Removal Socket 7. Fit the cartridge removal socket and ‘O’ Key (supplied) onto the cartridge nut and turn anticlockwise. Unscrew fully and pull the cartridge from the mixer body. Rotate the Cartridge 180°. 9. Make sure that the two cartridge inlet seals are fitted and carefully push into the body, aligning the cartridge lugs into the body slots. Note! Check that the cartridge lug stamped ‘H’ is aligned with the hot inlet supply. Important! Take care when fitting the cartridge as damage to the cartridge inlet seals may result in dripping from the shower head. 10. Tighten the nut by turning the ‘O’ key and the cartridge removal socket clockwise. Indicator Trim Internal View Valve Body Indicator Trim Cut out Handle Trim...
  • Page 19 (Rear View of Handle) Screw Front View of Mixer 14. Fit the handle using the washer and screw. Note! Make sure the washer is fitted as handle may come loose during use. 15. Tighten the screw to secure the handle. Mira Virtue Logo Bezel Lugs Alignment with Handle Back View Front View Handle Ceramic Bezel Installed Ceramic Bezel 16. Press and rotate the ceramic bezel clockwise by 90° to refit. Careful! There is...
  • Page 20: Maximum Temperature Setting

    Commissioning Maximum Temperature Setting Before using the shower, the maximum temperature must be checked to make sure that it is at a safe level. It has been preset to a safe showering temperature under ideal conditions at the factory, appropriate for most systems. However, site conditions and personal preference may make it necessary to reset this temperature. Note! Make sure that the hot water temperature is at least 55°C and that there is sufficient supply. 1. Turn on the shower to the maximum temperature (i.e. fully anticlockwise) and allow the temperature to stabilise.
  • Page 21 13. Refit the handle trim. 14. Fit the handle using washer and screw. Careful! Ensure that washer is assembled when refitting the handle as this could lead to corrosion. 15. Tighten the screw to secure the handle. Mira Virtue Logo Bezel Lugs Alignment with Handle Back View Front View Handle...
  • Page 22: Operation

    Operation Mira Virtue Mixing Valve The Mira Virtue thermostatic mixer is a thermostatic shower control with a single control handle for on/off and temperature control. The Control handle operates anti-clockwise in the following sequence: Maximum Pre-set • Temperature • • Cold • • Maximum Pre-set Temperature Maximum Pre-set Temperature Mira Virtue with Diverter The Mira Virtue thermostatic mixer is a thermostatic shower control with a single control lever for on/off and temperature control.
  • Page 23: User Maintenance

    Periodic attention is given, when necessary, to maintain the product in good functional order. The Mira Virtue thermostatic mixer is designed to need only minimal maintenance in normal use. The only serviceable parts are the inlet filters which should be checked and cleaned every 12 months. If a malfunction occurs with the thermostatic cartridge then this will necessitate a complete cartridge replacement.
  • Page 24 Unscrew the inlet and outlet connectors. Remove the shower control. 5. Remove the filters. 6. Clean the filters under a jet of water to remove any lodged particles or replace them. Reassembly is the reversal of the above procedure. Turn on the hot and cold water supplies and check for leaks. Mira Virtue with Diverter Parking Socket Sleeve Make sure the split in the sleeve is at the back Tighten Screw Through Here...
  • Page 25: Fault Diagnosis

    Fault Diagnosis Only use genuine Kohler Mira replacement parts. If you require a Mira trained service engineer or agent, please see ‘Customer Service’ on the back cover of this guide. Symptom Cause Recommended Action Only hot or cold water Inlets reversed (hot supply Check the filters for any from the mixer outlet.
  • Page 26: Spare Parts

    Spare Parts Mira Virtue 1735.123 1735.124 Overhead Bracket Overhead Pipe 1735.158 Nut and Olive 1735.125 Showerhead 1735.121 Riser Pipe Assy 1735.109 Inlet Pack (x2) 1735.110 Outlet Connector 162476 Backplate 1735.111 Valve Body Assy 1663.155 Filter Pack (x2) 1927.010 1735.111 1927.012 Valve Body Assy Handle Assy 1735.111...
  • Page 27 Mira Virtue with Diverter 1735.124 1735.123 Overhead Pipe Overhead Bracket 1735.120 Diverter Assy 1735.158 Nut and Olive A, B 1735.125 Showerhead A, B A, B 1735.119 1735.118 Hose Sleeve Diverter Lever 1735.117 Parking Socket 1735.110 Outlet Connector 162476 1735.111 Backplate Valve Body Assy 1663.155...
  • Page 28: Customer Service

    CustomerServiceEire@mirashowers.com commissioned in accordance with our instructions. If this does not resolve the issue, contact us for help and advice. Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifications without notice.

Table of Contents