10. The case has thinned sections that
can be removed to allow entry of the
supply pipe and electrical cables.
Remove the top thinned section of the
case for a falling supply, or remove the
bottom thinned section of the service
tunnel for a rising supply.
11. If the electrical cables enter from
above or below, remove an additional
thinned section for the electrical
cable. Do not remove any case if
the electrical cables enter from the
back.
12. Secure the shower to the wall loosely
through the top and side fixing holes,
using the supplied screws.
13. Mark the position of the bottom fixing
hole.
14. Remove the shower from the wall. Drill
the bottom fixing hole and insert the
supplied wall plug.
15. Replace the shower on the wall and
secure through the three fixing holes,
using the supplied screws.
16. Thoroughly flush the mains-fed cold
water supply pipe. The supply must be
clean and free from debris BEFORE
connecting the appliance.
17. Connect the inlet supply pipe to the
inlet connector using a 1/2" BSP nipple
with compression nuts and olives
(as shown) or a push-fit connector.
Thinned Section
Service Tunnel
Thinned Section
Inlet Connector
Compression Nut
Olive
1/2'' BSP Nipple
Olive
Compression Nut
Inlet Supply