IMPORTANT SAFETY INFORMATION

Warning!

1.
Read all of these instructions and retain this guide for later use.
2.
Products manufactured by us are safe and risk-free, provided that they are
installed, used and maintained in good working order, in accordance with our
instructions and recommendations.
3.
THIS APPLIANCE MUST BE EARTHED. MAKE SURE SUPPLEMENTARY
BONDING COMPLIES WITH THE 'REQUIREMENTS FOR ELECTRICAL
INSTALLATIONS' BS7671.
4.
This product is suitable for installation within Zone 1 and is rated IP X4.
5.
This product is not suitable for areas with very high humidity (i.e steam rooms).
Please consult your installer.
6.
In accordance with 'The Plugs and Sockets etc. (Safety) Regulations' in force at
the time of installation, this appliance is intended to be permanently connected
to the fixed electrical wiring of the mains system.
7.
Turn off the electrical and water supplies before commencing installation. The
electricity must be turned off at the mains and the appropriate circuit fuse
removed, if applicable.
8.
Refer to the wiring diagram before making any electrical connections.
9.
This appliance must be provided with means for disconnection that is incorporated
into the fixed wiring in accordance with the relevant local wiring regulations
10. Make sure all electrical connections are tight, to prevent overheating.
11. DO NOT twist the individual cable cores of the live and neutral conductors, as
this will prevent them from entering the terminal block.
12 Switch off the appliance at electrical isolating switch when not in use. This is
for safety and is recommended with all electrical appliances.
13. DO NOT install the product in a position in which service access is restricted.
14. DO NOT install the appliance in a position where it may become frozen.
15. Make sure that any pipework that could become frozen is properly insulated.
16. DO NOT switch on if there is a possibility that the water in the appliance is
frozen. The shower unit must not be fitted where it may be exposed to freezing
conditions.
17. The water supplies to this product must be isolated if the product is not to be
used for a long period of time. If the product or pipework is at risk of freezing
during this period they should also be drained of water.
18. DO NOT fit any form of outlet flow control as the outlet acts as a vent for the
tank body. Only Mira Showers recommended outlet fittings should be used.
19. If water leaks from the pressure relief valve, maintenance will be required before
the appliance can be safely used.
20. If the shower is dismantled during installation or servicing then upon completion
the product must be inspected to ensure there are no leaks.