Malfunction
Turning the
temperature knob
does not affect the
water temperature.
No water or very low
flow rate.
Cause
The flow regulator is faulty.
The handset sprayplate is
blocked.
The handset sprayplate is
blocked.
The incoming water
supply stop valves, or the
appliance isolating valve, is
closed.
The hose or handset is
blocked.
Insufficient water supply
pressure.
The heater tank is
excessively scaled.
The pilot valve is faulty.
The inlet filter is blocked.
The power is not turned on
at the double pole switch.
The fuse is blown or the
MCB/RCD has been
tripped, indicating a
possible electrical fault;
for example, heater tank
element failure.
Replace the flow regulator.
Remove and clean the handset
sprayplate. Refer to the shower
fittings User Guide. If the fault
persists, contact Customer
Services.
Regularly clean the handset
sprayplate.
Open the stop/isolating valve
completely.
Clear the blockage or replace the
hose or handset.
Contact the local water authority.
Replace the heater tank.
Replace the flow regulator
assembly.
Clean the inlet filter. Refer to
Maintenance: Cleaning the Inlet
Filter section.
Switch on the power at the double
pole switch.
Renew the fuse or reset the MCB/
RCD. If the fault persists, contact
Customer Services. Replace the
heater tank.