Component Functions - Heatilator PT60 Owner's Manual

Zero clearance pellet fireplace installation and operation
Table of Contents

Advertisement

B. Component Functions
1. Auto-Clean Motor
Location: Behind and under the fi repot on the left side, inside
the convection air chamber
Function: It automatically opens and closes the fi repot fl oor
so ashes can fall into the ash pan.
2. Auto-Clean Switch
Location: On top of the auto-clean motor
Function: Communicates to the control board when the fi repot
fl oor is open and when the auto-clean system has completed
its cycle and is back in the home (closed) position.
3. 12 Volt Battery Back-Up Cable (Optional Accessory)
Location: Plugs into the appliance at the lower left front of
the appliance.
Function: An icon will display on the wall control when the
appliance has lost main power and is running on battery
back-up.
4. Combustion (Exhaust) Blower
Location: Mounted in the bottom right rear of appliance.
Function: Pulls the exhaust from the appliance and pushs it
out through the venting system.
5. Control Board
Location: Lower left side of appliance.
Function: Controls the functioning of the appliance and
communicates with the wall control. The control board can
only be opened by an authorized dealer.
6. Convection Blower
Location: Mounted at the bottom left rear of the appliance
Function: Pushes heated air through the heat exchange
system into the room.
7. Door Switch
Location: Mounted on the right side of the fi rebox behind
the door handle
Function: Senses when the door is open and will display an
icon on the wall control and will turn off the auto-clean system
and feed motor for safety.
8. Feed System
Location: On the right side of the appliance and can be
removed as an entire assembly. The assembly includes
the feed motor, mounting bracket, bearing and feed spring
(auger).
Function: The hollow feed spring (auger) pulls pellets up the
feed tube from the hopper area and drops them down the
feed chute into the fi repot
April 29, 2011
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF
THE APPLIANCE.
9. Firepot
Location: Inside fi rebox and is made of high quality ductile
iron.
Function: The fl oor of the fi repot automatically opens for
cleaning and is operated by the auto-clean fi repot system.
The fl oor needs to return to a completely closed position or
the appliance will not operate properly.
10. Fuses
Location: One
AC fuse and one DC fuse is located on the
inside of the control board and a third fuse is located in the
power supply. Figures 54.1 & 54.2 on page 54.
Function:
The AC fuse operates the igniter and the DC
fuse operates all of the other components.
protects the components in the power supply. A fuse will
blow should a short occur and shut off power to the appli-
ance. The fuses can only be replaced by an authorized
dealer.
11. Heat Exchanger
Location:
Behind the baffl e.
to access the heat exchanger.
Function:
Transfers heat from the exhaust system into the
convection air chamber.
12. Hopper Lid Switch
Location: Lower
front right side of appliance on the power
switch cover.
Function:
Senses whether the hopper lid is open and dis-
plays an icon on the wall control and will turn off the feed
motor.
13. Interlock Switch
Location: Lower
front right side of appliance behind power
switch.
Function: Causes the auger to stop functioning and will be
opened when the appliances slides are extended.
14. Igniter (Heating Element)
Location:
Mounted on the base of the fi repot.
Function: Combustion air travels over the red hot igniter
creating super heated air that ignites the pellets or other
fuels.
15. Power Receptacle
Location:
Lower rear of the appliance
Function: Check the wall receptacle for 120 volt, 60 Hz
(standard current). Make sure the outlet is grounded and
has the correct polarity.
7051-507
POINTE Pellet Fireplace
The third fuse
Remove the cast iron baffl e
Page 53

Advertisement

Table of Contents
loading

Table of Contents