C. Frame the Fireplace
Figure 26.1 shows typical framing using combustible materials (2x4 lumber shown).
•
Framing across the top of fi replace must be above top standoffs.
•
See page 33 for detailed information regarding sub-fl oor material requirements.
C
B
Figure 26.1 - Framing the Fireplace
Page 26
Header MUST NOT
be notched!
D = extra space needed
for securing fireplace to the floor
D
and for outside air connection if
A
it is installed on side of fireplace
See Section 8 for outside air locations.
Outside Air is REQUIRED for all installations.
inches
mm
*
If interior of chase will be drywalled, add the thick-
ness to this measurement.
** Adjust header height for a raised platform under
fi replace, Taking into consideration the maximum
height allowed for loading fuel into the hopper.
7051-507
A
B*
C**
27-1/2
30
38-1/4
699
762
972