Section 3: Maintaining & Servicing Appliance Proper Shutdown Procedures; Quick Reference Maintenance Chart - Heatilator PT60 Owner's Manual

Zero clearance pellet fireplace installation and operation
Table of Contents

Advertisement

POINTE Pellet Fireplace
3
Maintaining & Servicing Your Appliance
A. Proper Shutdown Procedure
• Set wall control to OFF on AUTOMATIC / MANUAL SET-
TING screen. Figure 14.1.
• Wall control screen will scroll through the following mes-
sages after setting to OFF.
• Shutdown
• Auto-Clean
• Off
Approximately 45 minutes after setting the wall control to
OFF, the appliance should be cool enough to touch. If so,
now you can turn the power switch to OFF and pull the
appliance foward on the rails.
There is an interlock switch next to the power switch that as
you slide the appliance out it will ensure the auto-clean system
and the auger will not run, but the blowers will operate.
After servicing, restart with the AUTO/MANUAL SETTINGS
screen. Figure 14.1.
B. Quick Reference Maintenance Chart
Cleaning or Inspection
Ash Pan - Burning Wood Pellets
Ash Pan - Burning Alternate Fuels
Ash Removal from Firebox
Auto-Clean Inspection
Blower, Combustion (Exhaust)
Blower, Convection
Door Latch Inspection
Firebox - Prepare for Non-Burn Season At end of heating season
Firepot - Burning Softwood Pellets
Firepot - Burning Hardwood Pellets
Firepot - Burning Alternate Fuels
Glass
Heat Exchanger & Drop Tube
Hopper
Venting System
NOTICE: These are recommendations. Clean more frequently if you encounter heavy
build-up of ash at the recommended interval or you see soot coming from the
vent. Not properly cleaning your appliance on a regular basis will void your
warranty.
Page 14
Frequency
Every 5 bags of fuel
Every 1 bag of fuel
More frequently depending on the
fuel type or ash build-up
More frequently depending on the
fuel type
More frequently depending on the
fuel type
More frequently depending on the
operating environment.
Prior to heating season
Every 5 bags
Every 3 bags
Every 1 bag
When clear view of fi repot
becomes obscured
Every 1 ton of fuel
Every 1 ton of fuel or when chang-
ing fuel types
More frequently depending on the
fuel type
7051-507
Before Servicing Your Appliance
CAUTION! SHOCK AND SMOKE HAZARD!
• Proper Shutdown Procedure must be followed.
• Smoke spillage into room can occur if appliance is not
cool before turning off power switch.
• Risk of shock if appliance is not turned off before servic-
ing appliance.
Automatic
Manual
Off
Figure 14.1
Follow the detailed instructions found in this
section for each step listed in the chart below.
Daily Weekly Every 2
OR
X
OR
X
OR
X
OR
OR
OR
OR
OR
OR
X
OR
X
OR
X
OR
X
OR
OR
OR
Monthly
Yearly
Weeks
X
X
X
X
X
X
X
X
April 29, 2011