Congratulations; Sample Of Safety/Serial Numer Label - Heatilator PT60 Owner's Manual

Zero clearance pellet fireplace installation and operation
Table of Contents

Advertisement

POINTE Pellet Fireplace
Read this manual before installing or operating this fi replace.
Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Heatilator appliance, you have
our assurance of commitment to quality, durability, and perfor-
mance.
This commitment begins with our research of the market,
including 'Voice of the Customer' contacts, ensuring we make
products that will satisfy your needs. Our Research and Devel-
opment facility then employs the world's most advanced tech-
nology to achieve the optimum operation of our stoves, inserts
LOCATION OF SERIAL NUMBER LABEL: Right Inside Edge of Outer Can (Fig. 2)
Tested and
O-T L
Portland
Listed by
Oregon USA
US
C
Made in U.S.A.
OMNI-Test Laboratories, Inc.
Fait Aux États-Unis
Report / Rapport
#061-F-75-6.2
Testing Lab & Report No.
LOCATION OF CLEARANCE TO COMBUSTIBLES LABEL: Left Hand Panel of Hopper (Fig. 3)
CAUTION
:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE
AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion
from the hopper under certain conditions. Maintain hopper seal in good condition. Do not overfill hopper.
ATTENTION:
CHAUD LORS DE L' O PÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L' E SPACE DÉSIGNÉ DE L' I NSTALLATION. LE CONTACT
PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L' É TIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas
suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ
Listed Solid Fuel Room Heater/Pellet Type. Also suitable for Mobile Home
Installation. This appliance has been tested and listed for use in Manufactured
Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E1509-04, ULC S628-93, ULC/ORD-C1482-M1990
Room Heating Pellet Burning Type, (UM) 84-HUD FOR USE ONLY WITH
PELLETIZED WOOD. SEE OWNER'S MANUAL FOR OTHER FUEL OPTIONS.
Input Rating: 52,000 BTU/HR.
Electrical Rating: 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.
DANGER: Risk of electrical shock. Disconnect power supply before
servicing.
Replace glass only with 5mm ceramic available from your dealer.
To start, set thermostat above room temperature, the appliance will light
automatically. To shutdown, set thermostat to below room temperature.
For further instruction refer to owner's manual.
Keep viewing and ash removal doors tightly closed during operation.
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation and
operating instructions. Contact local building or fire officials about
restrictions and inspection in our area.
WARNING: FOR MOBILE HOMES: Do not install appliance in a sleeping
room. An outside combustion air inlet must be provided. The structural
integrity of the mobile home floor, ceiling and walls must be maintained.
Refer to manufacturer's instructions and local codes for precautions
required for passing chimney through a combustible wall or ceiling.
Inspect and clean vent system frequently in accordance with
manufacturer's instructions.
Components required for all installations: Outside Air Kit, Part Number
OAK-3.
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.
Use a 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
A Standoff to Side Walls
0 in. (0mm)
B Standoff to Back Wall
0 in (0mm)
C Top Standoff to Header
0 in (0mm)
D Vent Pipe to Combustible
*
E Floor Protection under Fireplace
None Required
* Use Pipe Manufacturer's Listed Clearances, 1 inch
(25mm) Minimum
F Floor Protection Hearth Extension From Door Opening 6 in (152mm)
G Floor Protection to the Side of Door Opening
F Portection du plancer agrandissement du foyer à ouverture du port: 6 in (152mm)
G Portection du plancer de côté à ouverture du port:
G
F
DO NOT REMOVE THIS LABEL
Page 2
Please retain this owner's manual for future reference.

Congratulations!

:
Manufactured by:
Fabriqué par
JAN
2009
2010
1445 Highway North, Colville, WA 99114
2011
www.heatilator.com
Manufacture Date
POINTE PELLET FIREPLACE
Appareil de chauffage de combustible solide/de type de boulettes. Accepté dans
l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage
dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
Testé à: ASTM #1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating. Pellet
Burning Type, UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS. VOIR LE
MANUAL DU PROPRIÉTAIRE POUR D'AUTRES OPTIONS DE CARBURANT.
Puissance de Rendement: 52,000 BTU/HR
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps,
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact
avant le service. Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible
chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le
poêle s'allumera automatiquement. Pour éteindre, descendre la température du thermostat en
dessous de la température de la pièce. Pour des instructions supplémentaires, référez vous au
manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres fermées
hermétiquement durant l'opération.
PRÉVENTION DES FEUX DE MAISON
Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant.
Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et
des inspections d'installation dans votre voisinage. Ne pas obstruez l'espace en dessous de
l'appareil.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une chambre à coucher. Un tuyau
extérieur de combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est
en usage. La structure intégrale du plancher, du plafond et des murs de la maison mobile doit
être maintenue intacte.
Référez vous aux instructions du fabricant et des codes locaux pour les précautions requises
pour passer une cheminée à travers un mur ou un plafond combustibles, et les compensations
maximums.
Inspectez et nettoyez la cheminée fréquemment.
Les composants requis pour tout l'installations. Assemblage d'air extérieur, Numéro de Pièce OAK-3.
Ne pas connecter cet appareil à une cheminée servant un autre appareil.
Utilitsez le système de ventilation de 3 or 4 inch (76-102mm) de diametre de type "L" ou "PL".
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
A Mur de arrières au poêle:
B
B Mur de côté poêle:
C
C Surfaces supérieurs à la boutisse
D Du conduits des combustibles
A
A
E Protection du plancer dessus cheminéel: Ne pas requis
*Voir le fabricant pour les espaces libres des
conduits enregistré, 1 inch (25mm) minimum
6 in (152mm)
6 in (152mm)
NE PAS ENLEVER L'ÉTIQUETTE
and fi replaces. And yet we are old-fashioned when it comes to
craftsmanship. Each unit is meticulously fabricated and surfaces
are hand-fi nished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality control
inspection.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance.
Thank you for choosing Heatilator
FEB MAR APR MAY JUNE
POINTE PELLET FIREPLACE
JULY AUG SEP OCT NOV
DEC
0 in. (0mm)
0 in. (0mm)
0 in. (0mm)
*
7051-507
007007
Serial Number
Open Front. Serial Number Label located
on right side inside edge of outer can.
Figure 2 - Serial Number Label
Slide fireplace out on the rails. Clearance
to Combustible Label located on left side of
hopper.
Figure 3 - Clearance to Combustibles
Label
April 29, 2011

Advertisement

Table of Contents
loading

Table of Contents