Through The Wall - Heatilator PT60 Owner's Manual

Zero clearance pellet fireplace installation and operation
Table of Contents

Advertisement

L. Through the Wall
Horizontal termination cap must be a minimum of 12 inches
(305mm) from the wall. Approved for mobile home installations.
Must use 3 or 4 inch (76mm-102mm) "L" or "PL" Listed pellet
venting and a Quadra-Fire Outside Air Kit in ALL installations.
Straight Out
Figure 45.1
NOTICE! See Section 8 "Avoiding Smoke and Odors" to minimize soot
damage to exterior walls of the house and to prevent re-entry of soot or ash
into the house for horizontal vent confi guration
45 Degree
Figure 45.2
April 29, 2011
0 in. (0mm) to Standoff
6 in.
(152mm)
Minimum
From Glass
Non-combustible
Hearth Extension
Illustration shows venting going in both directions.
Choose which one is best for your installation.
12 in. (305mm)
Minimum
Wall
Thimble
1-16 in.
(27mm)
Minimum
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365
Horizontal
W all
T ermination
Thimble
Cap
12 in.
(305mm)
Minimum
12 in. (305mm)
Minimum
1-1/6 in.( 27mm)
Minimum
7051-507
POINTE Pellet Fireplace
Page 45