RCS20 M:N Redundancy Switch
User Interfaces
4.3.3.5
SWITCH MAJOR ALARMS 1
These screens display the RCS20 major alarms, and allow the user to mask these alarms. When
an alarm is masked, the error will not be reported on the front panel MAJOR ALARM lamp nor
on the ALARM connector at the rear of the RCS20. The RAM/ROM alarm indicates a failure of
the RCS20 internal memory. The BACKUP UNAVAILABLE alarm indicates that a prime
channel modem has failed, but there was no backup channel modem available for backup, causing
prime channel traffic to be dropped. The BACKUP ERROR alarm indicates that the prime
channel modem configuration could not be loaded to a backup channel modem, thus a required
automatic backup could not take place, causing prime channel traffic to be dropped.
Programming steps:
1. Press
or
2. Press <TOG MODE> to toggle between YES and NO. 'Y' indicates an alarm is masked, 'N'
indicates an alarm is not masked.
3. Press <CLR> or <NEXT> to abort programming (no switch parameters will be changed).
4. Press <ENT> to load the information on the screen into the switch parameter table.
Masking alarms may cause undesirable modem performance
Key
Label
S1
S2
S3
Y/N
S4
NEXT
Numeric
---
Keypad
SWITCH MAJOR ALARMS
RAM/ROM
BACKUP UNAVAILABLE
ERROR DURING <BACKUP>
to move the flashing cursor the channel to be programmed
Function
Press to move the blinking cursor up through the list of faults.
Press to move the blinking cursor down through the list of faults.
Used to toggle between YES (masked) and NO (not masked).
Press to cycle to the next screen.
Press <CLR> or <NEXT> to abort programming (no switch parameters will
be changed).
Press <ENT> to load the information on the screen into the switch
parameter table.
MASK
: PASS
NO
: FAIL
NO
: FAIL
YES
Y/N
NEXT
4–65
Rev. 14
MN-RCS20